DGPS MAX Reference Manual
133
8.
Troubleshooting
Use the following checklist to troubleshoot anomalous DGPS MAX
receiver operation. Table 6-1 provides a problem symptom, followed by a
list of possible solutions.
Table 6-1 Troubleshooting
Symptom
Possible Solution
Receiver fails to power
•
Verify polarity of power leads
•
Check 1.5 A in-line power cable fuse
•
Check integrity of power cable connections
•
Check power input voltage (9.2-48 VDC)
•
Check current restrictions imposed by power
source (maximum > 1.0 A)
No data from DGPS MAX
•
Check receiver power status (display
illuminated?)
•
Verify that DGPS MAX is locked to a valid
DGPS signal (DGPS lock symbol engaged)
•
Verify that DGPS MAX is locked to GPS
satellites (GPS Lock symbol engaged)
•
Check integrity and connectivity of power and
data cable connections
•
Verify DGPS MAX Mode of operation
•
Potentially, the volume of data requested to be
output by the RX 400p could be higher than
the current baud rate supports. Try using
19,200 as the baud rate for all devices.
Random data from DGPS
MAX
•
Verify that the RTCM or the Bin95 and Bin96
messages are not being output accidentally
(check the
NMEA Output@
menu)
•
Verify baud rate settings of DGPS MAX and
remote device
No GPS lock
•
Check integrity of antenna cable
•
Verify DGPS MAX antenna port output voltage
(5 DC)
•
Verify CDA-2MAX’s unobstructed view of the
sky
•
Verify antenna cable length < 10 meters
No WAAS lock
•
Check antenna connections
•
Verify 5 VDC across antenna cable
Содержание DGPS MAX
Страница 1: ...DGPS MAX Reference Manual Part Number 875 0034 001 Date March 2004 ...
Страница 14: ...DGPS MAX Reference Manual xiv ...
Страница 20: ...DGPS MAX Reference Manual xx ...
Страница 31: ...DGPS MAX Reference Manual 11 Figure 1 3 WAAS Coverage ...
Страница 142: ...DGPS MAX Reference Manual 122 ...
Страница 158: ...DGPS MAX Reference Manual 138 ...
Страница 168: ...DGPS MAX Reference Manual 148 ...
Страница 172: ...DGPS MAX Reference Manual 152 ...