Crystal Vision
Problem solving
TANDEM-200 User Manual R1.7
137
13/02/2008
Further help
Other Status menus such as the Status Only menus discussed in section 8.2 and the
Ancillary Data Status menu discussed in section 8.2/8.8 will also prove to be useful
during fault finding.
It is also useful to listen to any valid audio destination with a pair of headphones using the
audio monitoring facility discussed in section 8.5
If the Auto menu is left as the default for the card edge display, (All MENU levers UP,
SEL position 0), then the first three status menus will be displayed on a priority basis.
This will provide continuous monitoring of SDI signal status, AES and Ref I/P status and
whether any active audio channels fall silent (<50dB FS). This is recommended for
normal operation.
Control cross reference
Piano switch
Hex switch
Description
Card-edge
section
Front panel
menu
all up
0 - 5
display status
9.2
1.1
6 - 9
select audio group
9.2, 9.4
1.2.1, 1.2.2
A, B
select audio monitor
9.2, 9.5
1.4
C, D
adjust audio delay
9.2, 9.4
1.2.3
E
adjust silence time
9.2, 9.4
n/a
F
GPI enable / disable
9.2. 9.6
1.3.2.4
2 only down
0 - 15
preset 0-15 save / recall
9.7
1.3.2
3 only down
0 - 1
display/select mode
9.12
1.3.1
2
SDI PLL mode
9.13
1.3.3
3 Re-sampling
On/Off 9.14 1.3.4
4
B format card test
9.15
n/a
5
Not used by TANDEM-200
9.15
n/a
6 - F
Factory use only
9.15
n/a
4 only down
0 - F
configure audio routing
9.4
1.2.4
5 only down
0, 1
select error handling level
9.8
n/a
2 - 5
embed / de-embed formats
9.8
n/a
6, 7
select stereo/dual mono
9.9
n/a
8, 9
contiguous pack (embed) –
always contig
9.8 n/a
A, B
Blank HANC
9.8
n/a
C, D
EDH on/off
9.8
n/a
E, F
adjust AES phase
9.10
n/a
6 only down
0-9
GPI output error masking
9.11
n/a
B load
default
settings 9.3
n/a
C
diagnostic data
n/a
n/a
D
firmware version number
9.12
Device
E, F
display ancillary data status
9.2, 9.8
n/a
7 only down
0-5
De-embedded signal status
10.5
1.1.1, 1.1.3
6-8 General
status
10.5
1.1
9-C
Output signal status
10.5
1.1.2, 1.1.4