Crystal Vision
Installation
2.4 Configuration Switches
The Indigo 2AE and Indigo 2SE CoolFlow frames both make use of a 6-way DIL configuration
switch mounted on the front panel CPU board to change the hardware configuration. The DIL
switch functions are identical for both frame types although the CPU boards are different.
Indigo 2AE
On the upper edge of the Indigo 2AE front panel PCB, the 6-way DIL configuration switches and
reset switch can be found. This PCB was fitted early 2015 –
see
for older frames
.
Indigo 2AE CPU board.
‘Reset’ switch on side of board
Indigo 2SE CoolFlow
The CPU board is mounted on the rear of the front panel. This PCB was fitted after August
2013 –
for older frames
. Also on this board is a status ‘
Link’
LED. This LED is
useful for troubleshooting the network link. The link LED will be illuminated whenever the frame
is connected to a network. Should this LED not be lit, check the cable connection between the
frame and network outlet. The ‘
Term’
switch terminates the RS422 chain which was used by
older pre-Ethernet enabled frames and is no longer supported by Crystal Vision.
Indigo 2SE CoolFlow CPU board
Indigo 2AE and 2SE User Manual R1.17
11