Appendix 2
used as the trap receiver. Then click on the ‘Store’ button to write the new value into the frame.
This will take a few seconds. You will then need to re-boot the frame (as described in the
"Resetting the Frame" below) for the setting to take effect.
Checking
The frame should now be ready for SNMP operation. You can check this by setting a SNMP
Manager, or MIB browser, to the frame IP address and performing an SNMP walk of the
‘private’ section of the Object ID tree.
See below for a screen shot of a successful walk; in this case of a (now obsolete) 4U frame
containing two boards.
If you do not see something similar to this, then the frame may need to be reset to activate the
SNMP licence. The frame will report the presence of the licence even if it has not been activated
by a reset. The same walk of an unlicensed frame gives the results below.
Indigo 2AE and 2SE User Manual R1.17
77