Содержание Storm Cafe

Страница 1: ...Service Manual Storm Caf Hot Cold and Coffee Dispenser...

Страница 2: ...2 Notes...

Страница 3: ...nosis and Replacement 17 Cold Control Replacement 17 Cold Control Adjustment 19 Hot Thermostat Limiter Replacement 20 Hot Tank Replacement 21 Compressor Relay Overload Replacement 24 SECTION 6 Cleanin...

Страница 4: ...torm Caf Power Rating Single Phase 100 115VAC 60Hz Standard Current 8 9 9 5A Power Cold 70W Consumption Hot 1000W Cold Compressor Single Phase Compressor Refrigerant Type R134a 32g Temperature Range 4...

Страница 5: ...5 Dimensional Drawing 45 172 1147 37 7 904 200 76 5 273 133 93 12 598 319 99 13 386 340 Dimensions are shown in Inches mm...

Страница 6: ...example to right AB F M 2 K H K 1 Cooler Shape Reservoir Type Type of Lid of Faucets Body Color Temp Option Insert Color Voltage Option AB Storm Coffee Brewer F SmartFlo Water Cartridge M Manifold 2...

Страница 7: ...C C150166 19 Spring SS Safety Button FAS C100116 20 Safety Button Red PLC C150126 21 PCB Switch Board ELE C100421 22 Top Cover Assembly 8 10 12 oz brew size SUB C200722 Top Cover Assembly 6 8 10 oz br...

Страница 8: ...w 1 2 3 4 7 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 25 24 23 26 27 28 29 30 31 32 33 31 34 35 36 37 38 39 40 41 42 43 44 45 47 48 46 49 50 51 52 53 54 55 56 58 57 59 60 61 62 63 64 65 66 67 68...

Страница 9: ...Valve Cold Reservoir Brewer Lid Switch Connector Blk Hot Switch Coffee UI PCBA Power Cord Hot Tank Limiter Hot Thermostat Cold Control Heater Control PCBA Blk Blk White G Y G Y White White White Tran...

Страница 10: ...th a cloth Fig 2 4 Remove label seal from the bottle cap if applicable and insert spike cap through the bottle cap do not remove bottle cap and press down to secure Fig 3 4 5 Insert the bottle adapter...

Страница 11: ...r to fill the cold water tank Fig 9 When water begins to flow in a steady stream from the cold faucet the tank has been filled approximately 1 minute although it may be less time Repeat the process wi...

Страница 12: ...Note To reset the life timer system the SmartFlo is required to be removed from the dispenser for a minimum of 15 seconds while the unit is connected to the mains power supply 1 Open Dispenser door Fi...

Страница 13: ...embly through Spike cap until tube hits bottom of the bottle Fig 18 19 8 Slide bottle into cabinet and close the door Fig 20 to Fig 22 Push door down to close 9 Place a container under faucet and disp...

Страница 14: ...sys tem has been pre set to provide indication after a period of 12 months of use Users may operate the cooler as normal until the bottle has been emptied Note To reset the timer system the SmartFlo...

Страница 15: ...se to release the two blue knobs Fig 11 12 Pull to remove the SmartFlo Water Cartridge and discard in recycling bin Fig 13 14 6 Install a new SmartFlo Water Cartridge Install the connector and corruga...

Страница 16: ...lectrical outlet Pull the cold faucet lever until a steady stream of water comes out Then push the hot safety button and press the hot water faucet lever to activate water flow Keep pressing the hot w...

Страница 17: ...ure that the water has been completely drained from the system 1 Turn off hot tank power switch located on the front panel inside the door Fig 1 and unplug the water cooler 2 Remove the upper back pan...

Страница 18: ...10 Note Care should be taken while installing the sensor tube that the protective cover within the evaporator insulation is in the proper position 8 Install a replacement zip tie to hold the sensor wi...

Страница 19: ...ly 1 hour position Allow the cooler to stabilize for 2 3 hours to ensure proper temperature of the cold water Note do not change the setting by more than 1 hour setting at a time to prevent freezing T...

Страница 20: ...gged the water drained and the upper back panel removed Tip Use a plier or flathead screwdriver to pry wire connecters off Fig 1 1 Remove the wire terminals from the thermostat or limiter and identify...

Страница 21: ...TO COOL BEFORE DRAINING 1 2 HOURS Tip Use a small flathead screwdriver to pry wire connectors off 1 Use the access key to open the top cover Release and open the latch Fig 1 Turn the two blue locking...

Страница 22: ...15 6 Remove the hot tank from cooler Fig 16 7 While holding the new hot tank with one hand align both tubes with the corresponding holes Fig 17 and 18 Tighten the three screws to attach the hot tankp...

Страница 23: ...t safety button and press the hot water faucet lever until water comes out Fig 19 CAUTION To prevent damaging the hot tank do not turn ON if the hot tank is empty 10 Slide door upward to open Turn the...

Страница 24: ...l flathead screwdriver to pry wire terminals and relay from compressor 1 Remove the relay overload cover by prying the metal clip to unhook it from the compressor on both sides Fig 1 2 2 Carefully rem...

Страница 25: ...25 4 Reinstall the cover Fig 12 and secure with the metal clip Fig 13 Note use caution not to damage wires Fig 12 Fig 13...

Страница 26: ...the conditions and environment Follow the steps outlined below for sanitizing the water cooler CAUTION DO NOT IMMERSE THE UNIT IN WATER OR CLEAN USING PRESSURE WASHER 1 Use nitrile gloves or wash hand...

Страница 27: ...ith the cooler top still open open the coffee pod holder Fig 15 Remove the coffee cup holder brown Fig 16 and discard or machine wash top rack only Turn the red twist locks on each side to release the...

Страница 28: ...g solu tion to the hot tank filling up to the top of the inlet approx 38 7oz 1100ml refer to Fig 25 Allow time for the solution to descale Drain and dispose of solution according to the manufacturer s...

Страница 29: ...two knobs to lock the SmartFlo in place Fig 33 34 14 Slide a clean pod holder onto the tabs on the side of the probe assembly and push downward into place Fig 35 Turn the two red twist locks to lock...

Страница 30: ...l it back onto cooler Plug the cooler into the electrical outlet Push the hot safety button and press the hot water faucet lever to activate water flow Keep pressing the hot water faucet lever until w...

Страница 31: ...e coffee pod holder using the Daily Cleaning procedures in this docu ment 3 Once the cleaned coffee pod holder is installed press the 8 10 or 12 oz option and press the Brew button to flush hot water...

Страница 32: ...in one hand turn it so that the bottom of the lid can be seen easily Fig 76 Locate the inlet needle in the lid s center Using a straightened paper clip locate and gently insert it into all of the ope...

Страница 33: ...move any grounds which might be sticking to the needle Fig 9 6 Reassemble the Rear Housing and the Pod Holder Assembly into the brewer module and close the lid 7 Place a 12 oz or larger container on t...

Страница 34: ...rd two flashes 3 If a problem with the NTC display board three flashes 4 If a coffee system problem flow meter solenoid tubing etc four flashes 5 If a problem with heating system five flashes 6 If a p...

Страница 35: ...l be re attached later in the process 3 If not already closed ensure that the coffee pod holder lid is closed Place containers under the coffee nozzle and the Hot tank drain on the rear of the machine...

Страница 36: ...not kinked or crimped Ensure SmartFlo Water Cartridge locking knobs in top are securely locked in place Not Cooling Optimum cold temperature will be reached after several hours of operation Ensure tha...

Страница 37: ...stal Mountain Products Inc 1000H Taylor Station Rd Gahanna OH 43230 Copyright 2020 Crystal Mountain Products Inc Manufactured under U S Patent No 10 781 093 and other patents pending Form 2007001 Rev...