Page 23
Calibrating a Data Source
Calibrating the displayed data is possible for many of the Data Sources. Press
and hold the
&
and
"
"
"
"
"
keys for ten seconds to enter the Calibration Editor (until
you hear a long beep). The data source value, display identifier (1, 2, 3, L or
r) and the word “CAL” will be displayed as shown in Figure 22. Quick press
the
&
key to select the desired display identifier (1, 2, 3, L or r). Press and
hold the
%
and
$
keys to change the calibration value. Press the
&
key for 1
second (until the long beep) to accept the new value, save it to memory and
leave the Calibration Editor mode.
When calibrating the Time-Of-Day clock a Clock Calibration value between 0
and 100 (nominal value is 50 ) will be shown on Display #1 and the time of day
shown on Display #3. Increase the Clock Calibration value to speed up the
clock, decrease the Clock Calibration value to slow down the clock. Increas-
ing the Clock Calibration value by one will increase the clock speed by 1
second per day. Decreasing the Clock Calibration value by one will decrease
the clock speed by 1 second per day.
Figure 24 - Calibration Editor
Editing the calibration for the Data
Source shown on digital display #2
Содержание MaxVu110
Страница 1: ...Page 1 CruzPro MaxVu110 User Configurable Multifunction Instrument...
Страница 10: ...Page 10 Figure 2 MaxVu110 Screw Terminal Connections...
Страница 12: ...Page 12...
Страница 35: ...Page 35...
Страница 46: ...Page 46 Appendix C Typical Setup...
Страница 47: ...Page 47...