Page 67
P470E
Zone is 24Hr - Default none Page 33
P471E
Zone is 24Hr Fire zone - Default none Page 33
P472E
Zone is 24Hr Non-Latching zone - Default none Page 33
P473E
Day zones - Default none Page 33
P474E
Continuous day zone - Default none Page 33
P475E
Siren lockout zones - Default none Page 33
P476E
Access control door position input - Default none Page 33
P477E
Access control request to exit input - Default none Page 34
** Multiple Zone Activation Reporting **
P478E
Zones 9-16 will report multiple activation's - default on Page 34
Zones 9-16 Monitored for Inactivity
P479E
Zones 9-16 will be monitored for inactivity - default none Page 34
Can Arm if Zone is Unsealed-Zones 9-16
P480E
Can Arm if Zone Unsealed-Zones 9-16 - default none Page 34
Partition “C” Primary Output Options
P481E-P488E OPTIONS
P481E
Area “C” primary options for output #1- Default 1
1 = Standard zone activation's Page 24
P482E
Area “C” primary options for output #2 - Default 1 & 2
2 = Stay Mode activation's Page 24
P483E
Area "C" primary options for output #3 - Default 1
3 = Radio key chirps Page 24
P384E
Area "C" primary options for output #4 - Default 1
4 = All zones sealed (ready) Page 24
P485E
Area "C" primary options for output #5 - Default 1 5 = 2 sec pulse on arm/disarm Page 24
P486E
Area "C" primary options for output #6 - Default 1 6 = Spare Page 24
P487E
Area "C" primary options for output #7 - Default 1 7 = Day zone activation's Page 24
P488E
Area "C" primary options for output #8 - Default 1 8 = Spare Page 24
** Dialler Reporting Options for partition “C” **
P489E
Area C reporting options -Default = 1,2 Page 28
1 = Send set / unset 5 = Send set at the end of the exit delay (LED On
2 = Send Stay Mode set/unset 6 = Send all zone restores at disarm only
3 = Send unset only after activation's 7 = Spare
4 = Send Stay Mode unset only after alarm 8 = Spare
Programming Partition “C” Parameters
P490E
Time zones used for Area "C" auto-arming/disarming - Default 0 Page 25
Partition “C” Specific Output Options
P491E-P498E OPTIONS
P491E
Area "C" specific options for output #1 - Default 0 1 = Any bypass Page 24
P492E
Area "C" specific options for output #2 - Default 0 2 = Auto-bypass warning
Page 24
P493E
Area "C" specific options for output #3 - Default 0 3 = Entry beeps Page 24
P494E
Area "C" specific options for output #4 - Default 0 4 = Exit Beeps Page 24
P495E
Area "C" specific options for output #5 - Default 0 5 = Control Page 24
P496E
Area "C" specific options for output #6 - Default 0 6 = Follow Set Arming Page 24
P497E
Area "C" specific options for output #7 - Default 0 7 = Follow Stay Arming Page 24
P498E
Area "C" specific options for output #8 - Default 0 8 = Follow Unset Page 24
Partition “C” Keypad Options
P499E
Arm key can disarm during exit - Default 1-8 Page 25
P500E
Stay key can disarm during Stay armed state - Default 1-8 Page 25
Partition “C” Misc Options
P501E
Misc partition options 1 - Default 0 1 = Cannot Arm if not sealed Page 26
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required for control
Содержание Arrowhead Elite V6