Page 26
P303E 1E = Arm area when time zone ends - Default off
2E = Disarm area when time zone starts - Default off
3E = Disable stay mode exit delay - Default off
4E = Disable arm mode exit delay - Default off
5E = Disable stay mode entry delay - Default off
6E = Disable arm mode entry delay - Default off
7E = Use special stay mode entry delay - Default off
8E = Send alarms and bypasses in stay mode - Default off
Option 1 Arm area when time zone ends
- this option will automatically arm area "A" when the time zone
programmed at address P290E finishes.
Option 2 Disarm area when the time zone starts
- this option will automatically disarm area "A" when the
time zone programmed at address P290E starts.
Option 3 Disable stay mode exit delay
- If this option is on the exit delay for area "A" becomes “0” when
arming stay mode (the delay will still apply to full arm unless option 4 is also on).
Option 4 Disable arm mode exit delay
- If this option is on the exit delay for area "A" becomes “0” when
arming the panel (the delay will still apply to stay mode unless option 3 is also on).
Option 5 Disable stay mode entry delay
- If this option is on then all zones are instant in stay mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in full
arm mode unless option 6 is also on).
Option 6 Disable arm mode entry delay
- If this option is on then all zones are instant in full arm mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in stay
mode unless option 5 is also on).
Option 7 Use special stay mode entry delay -
If this option is on then all zones use the special Stay
Mode entry delay (P540E) in stay mode and the normal delays programmed at addresses
P511E - P526E are ignored.
Option 8 Send alarms and bypasses in stay mode -
If this option is on then all alarms and zone
bypasses in Stay mode will be reported via the dialler in Contact ID. Only zone alarms will be
reported if using Domestic/ Voice or Pager reporting formats. You should also note that if a Stay
mode alarm is not kissed off in Domestic/ Voice or Pager mode and the alarm is not disarmed,
when the dialler test time comes around, the zone alarms will report again. If this is not desired
you can stop this from happening by turning of all days for the test time at address P815E.
Note: P403E is the same as above but applies to Area B Time & Delay options
Note: P503E is the same as above but applies to Area C Time & Delay options
PARTITION "A" MISCELLANEOUS KEYPAD OPTIONS
- P301E
PARTITION "B" MISCELLANEOUS KEYPAD OPTIONS
- P401E
PARTITION "C" MISCELLANEOUS KEYPAD OPTIONS
- P501E
P301E 1E
=
Cannot Arm if not Ready
2E = Arm key required before code to set
3E = Stay key required before code to arm Stay Mode
4E = Code required to arm area
5E = Control function requires code
6E = Control function toggles
7E = Control function is momentary
8E = Control Button disables "Day/Chime" mode or directly Controls Outputs
Option 1
Cannot Arm if not Ready -
This option if turned on will inhibit arming of Area “A” if any zone in area A
is unsealed (Not Ready). If the option is off, the area can be armed with zones unsealed but the panel
will either auto-bypass the zone or go into alarm at the end of the exit delay depending upon other option
settings. If required, certain zones can be exempted from this feature if they are in low security areas,
allowing the area to be armed with a zone/s unsealed, by selecting the zones at addresses P460E &
P480E. This option does not apply to Stay mode.
Option 2
Arm key required before code to arm
- This option determines if the "ARM" key must be pressed
before a code is entered to arm Area "A". This option must be enabled where a keypad is assigned to