Page 30
Option 1
Cabinet tamper is loop or end-of-line
- This option determines if the Cabinet tamper input uses
a closed loop or 2k2 end-of-line resistor. If this option is on the tamper is a 2k2.
Option 2
Key-switch input is loop or end-of-line
- This option determines if the Key-switch input
uses a closed loop or 2k2 end-of-line resistor. If this option is on the 2k2 resistor must be fitted.
Option 3
Low Key-switch is momentary or latching
- This option determines if the low Key-switch (4k7)
is momentary or latching. If option 3 is on the low Key-switch will be momentary.
Option 4
High Key-switch is momentary or latching
- This option determines if the high Key-switch
(8k2) is momentary or latching. If option 4 is on the high Key-switch will be momentary.
Option 5
Send Output data to keypad buss
- This option allows the output updates to the keypad buss for
the OUTPUTX4 board to be turned off if not needed. The LED Off means no updates to the buss.
ZONE PROGRAMMING
SOAK TEST ZONES - P408E - P409E
If a zone is suspected of being faulty, it may be disabled by making it a Soak-test zone (excludes 24 hr Zones). This
means that the zone will not cause an alarm or report via the dialler, but it will still be active during the Armed state.
In this way any potential activations can be monitored via the event memory for a period of time to determine whether
the detector connected to the zone input is faulty or not without creating nuisance alarms. Following any tests, if the
zone is found to be OK, the Soak-test mode can be turned off for that zone which then returns it back to full
operation.
P408E SOAK-TEST ZONES
- 1-8
P409E SOAK-TEST ZONES
- 9-16
ZONE VIBRATION SETTINGS
- P411E - P418E
Only the first 8 zones may be defined as vibration sensor zones with a vibration sensitivity level as required. If a
value other than zero is assigned at addresses P411E to P418E the zone which has been assigned that value
automatically becomes a vibration zone. To turn a vibration zone back into a normal zone assign a zero value at the
relevant address. Zero is the default setting.
P411E 0-8E
Zone 1 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P412E 0-8E
Zone 2 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P413E 0-8E
Zone 3 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P414E 0-8E
Zone 4 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P415E 0-8E
Zone 5 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P416E 0-8E
Zone 6 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P417E 0-8E
Zone 7 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
P418E 0-8E
Zone 8 vibration sensitivity
- Where 0 = none, 1 is highest and 8 is lowest sensitivity level.
SINGLE OR DUAL ZONE INPUT (8 or 16 zones)
- P410E
P410E 1-8E
Single or dual zone input
- This option is used to define the Elite as an 8 or 16 zone panel
where options 1-8 represent zone inputs 1-8. If a LED is on at this address it means that zone
input has been assigned "Zone Doubling" whereby the zone input is used for both a low (1-8) and
a high (9-16) zone. When zone doubling is used, zone 1 input is used for zones 1 & 9, Zone 2
input is used for zones 2 & 10, zones 3 input is used for zones 3 & 11 etc. Zone doubling is
assigned on a zone-by-zone basis.
SHORT CIRCUIT OR END OF LINE ZONE INPUT
- P419E
P419E 1-8E
Short Circuit or End-of-line -
This option controls whether the individual zone inputs require a
2k2 end of line (EOL) resistor or not. If zone doubling is turned off (LED off) for an input at
address P410E and the corresponding input at this address is also off (LED off) then the input
only requires a short circuit loop (no EOL) to seal the input and an open circuit is seen by the
panel as an alarm. If this option is on and zone doubling for the same input is off then the input
requires a 2k2 resistor to seal the input and if the 2k2 resistor is shorted out or open circuited then
an alarm is created. If this option is off and zone doubling is on then there is no tamper monitoring
on the input and only a 4k7 and 8k2 resistor are required for the two zones, an open circuit on the