Page 20
Option 6
Output mapped to Local Command Control
- This option is used to map an output to the local
command control feature whereby the output can be controlled directly from the keypad. The DTMF
command control code at address P371 is used for this local control function.
Option 7
Day Zones Linked to Pulse Timer
- Day Zones programmed to operate this output will pulse the output
at the rate programmed for the pulse timer (e.g. if it is output #1 then the timer at P571E applies).
Option 8
Pulsed 24 hour alarm
- If a 24 hour zone activates the alarm this option will cause the output to pulse at
a rate equal to the value set for the pulse timer for this output. This feature is provided to differentiate
between a burglar and fire alarm using the same siren.
P202E - P208E
As per P201E above for Outputs 2-8
SPECIAL ALARMS TO OUTPUT OPTIONS - P211E - P218E
In this block of addresses P211E relates to output #1, P212E relates to output #2 etc
P211E 1E = Keypad Panic Alarm to Output #1
2E = Keypad Fire Alarm to Output #1
3E = Keypad Medical Alarm to Output #1
4E = Duress Alarm to Output #1
5E = Wrong Code Tamper Alarm to Output #1
6E = Radio Key Panic Alarm to Output #1
7E = 24 Hour Zone Alarm to Output #1
8E = 24 Hour Fire Zone Alarm to Output #1
Option 1
Keypad Panic to Output
- This option is used to map the operation of the keypad panic button to an
output i.e. when the Panic button (or 1 & 3) on a keypad is pressed any output with this option enabled
will turn on.
Option 2
Keypad Fire Alarm to Output
- This option is used to map the operation of the keypad Fire Alarm
(buttons 4 & 6) to an output i.e. when the Fire Alarm (4 & 6) on a keypad is pressed any output with this
option enabled will turn on.
Option 3
Keypad Medical Alarm to Output
- This option is used to map the operation of the keypad Medical
Alarm (buttons 7 & 9) to an output i.e. when the Medical Alarm (7 & 9) on a keypad is pressed any
output with this option enabled will turn on.
Option 4
Duress Alarm to Output
- This option is used to map a Duress Alarm to an output. A Duress Alarm is
generated when the alarm is unset by a valid user that adds the duress digit to the beginning of their
code.
Option 5
Wrong Code Tamper Alarm to Output
- This option is used to map the Wrong Code Tamper Alarm to
an output. A Wrong Code Tamper Alarm is generated if an invalid code is entered more than 4 times at
a keypad. This option will cause the output to turn on when this alarm condition is present.
Option 6
Radio Key Panic Alarm to Output
- This option is used to map the operation of the Radio Key Panic
Alarm to an output i.e. when the Radio Panic is generated any output with this option enabled will turn
on.
Option 7
24 Hour Zone Alarm to Output
- This option is used to map 24 Hour Zone Alarms to an output i.e.
when the 24 Hour Zone Alarm is generated any output with this option enabled will turn on.
Option 8
24 Hour Fire Zone Alarm to Output
- This option is used to map 24 Hour Fire Alarm to an output.
When the 24 Hour Fire Alarm is generated this will cause the output to flash at a rate set by the pulse
timer for this output to identify the difference between a fire alarm and normal burglar alarm.
SECONDARY SPECIAL ALARMS TO OUTPUT OPTIONS
- P221E - P228E
In this block of addresses P221E relates to output #1, P222E relates to output #2 etc
P221E 1E = Zone Tamper Alarm to Output #1
2E = System Tamper Alarm to Output #1
3E = Mains Failure to Output #1
4E = Panel Battery Low to Output #1
Содержание Arrowhead Elite V6