Page 66
Zone Response Time Settings
P420E
Zone response settings default = 6 (value 1-31E) Page 31
** System Events to Scenario Mapping **
P421E
Area A reports mapped to scenario 1-4 default 1 Page 50
P422E
Area B reports mapped to scenario 1-4 default 1 Page 50
P423E
Area C reports mapped to scenario 1-4 default 1 Page 50
P424E
Keypad “Panic” (& buttons 1 & 3) mapped to scenario 1-4 default 1 Page 50
P425E
Keypad “Fire” (buttons 4 & 6) mapped to scenario 1-4 default 1 Page 50
P426E
Keypad “Medical” (buttons 7 & 9) mapped to scenario 1-4 default 1 Page 50
P427E
Battery low mapped to scenario 1-4 default 0 Page 50
P428E
Mains fail mapped to scenario 1-4 default 1 Page 50
P429E
Phone line restore mapped to scenario 1-4 default 1 Page 50
P430E
Radio PIR battery low mapped to scenario 1-4 default 1 Page 50
P431E
Radiokey battery low mapped to scenario 1-4 default 1 Page 50
P432E
Keypad tamper mapped to scenario 1-4 default 1 Page 50
P433E
Cabinet tamper mapped to scenario 1-4 default 1 Page 50
P434E
Radio panic mapped to scenario 1-4 default 1 Page 50
P435E
Test calls mapped to scenario 1-4 default 1 Page 50
P436E
Duress Alarm mapped to scenario 1-4 default 1 Page 50
P437E
Supervised Radio Timeout mapped to scenario 1-4 default 1 Page 50
P438E
Zone Inactivity Timeout mapped to scenario 1-4 default 1 Page 50
Low Zone Assignments (Zones 1-8)
P441E
Zone is in Area "A" - Default all ) Page 31
P442E
Zone is in Area "B" - Default none ) If zone is in both it is then a partition "C" zone Page 31
P443E
Zone is a normally open/closed output - Default N/C 0ff = N/C On = N/O Page 31
P444E
Zone is a radio detector - Default 0ff Page 31
P445E
Stay mode zones - Default zones 1-4 Page 31
P446E
Zone can be bypassed - Default all Page 31
P447E
Auto-bypass zones - Default all Page 31
P448E
Zone is a handover - Default none Page 31
P449E
Two trigger zones -Default none Page 31
P450E
Zone is 24Hr - Default none Page 31
P451E
Zone is 24Hr Fire zone - Default none Page 32
P452E
Zone is 24Hr Non-Latching zone - Default none Page 32
P453E
Day zones - Default none Page 32
P454E
Continuous day zone - Default none Page 32
P455E
Siren lockout zones - Default none Page 32
P456E
Access control door position input - Default none Page 32
P457E
Access control request to exit input - Default none Page 32
** Multiple Zone Activation Reporting **
P458E
Zones 1-8 will report multiple activation's - default on Page 32
Zones 1-8 Monitored for Inactivity
P459E
Zones 1-8 will be monitored for inactivity - default none Page 32
Can Arm if Zone is Unsealed-Zones 1-8
P460E
Can Arm if Zone Unsealed-Zones 1-8 - default none Page 32
High Zone Assignments (Zones 9-16)
P461E
Zone is in Area "A" - Default all ) Page 32
P462E
Zone is in Area "B" - Default none ) If zone is in both it is then a partition "C" zone Page 32
P463E
Zone is a normally open/closed output - Default N/C 0ff = N/C On = N/O Page 32
P464E
Zone is a radio detector - Default 0ff Page 33
P465E
Stay mode zones - Default zones none Page 33
P466E
Zone can be bypassed - Default all Page 33
P467E
Auto-bypass zones - Default all Page 33
P468E
Zone is a handover - Default none Page 33
P469E
Two trigger zones -Default none Page 33
Содержание Arrowhead Elite V6
Страница 81: ...Page 81 ...