background image

Instruction Manual

                    

Model 1582-14  

Data Switch  

June 2009   Rev. A   

SWITCH A

MODEL 1582

POWER

1      2

   AUTO   

 CROSS TECHNOLOGIES, INC.

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

SWITCH B

   AUTO   

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB:  www.crosstechnologies.com 

E-MAIL:  [email protected]

Содержание 1582-14

Страница 1: ...n are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...anship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subasse...

Страница 3: ...nd CH2 are in alarm 3 Minimum Auto switching Initial Channel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to Auto if both channel alarms are clear o...

Страница 4: ...arm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected...

Страница 5: ...N 1 2 4 6 7 9 Not connected J8 Monitors and Cont trols Controls Connec ctor J8 Monitors and Controls Connector Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 a...

Страница 6: ...RM CH2 LED Turns red when Channel 2 clock times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT Switch 3 position switch as follows LEFT manually sele...

Страница 7: ...el 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cle...

Страница 8: ...tion DIP switch Selects the Initial Channel Select mode when JP1 2 3 JP101 102 103 in Dot and JP4 JP104 in Non dot S3 S103 positions 1 2 3 4 to ON ICS is enabled In the ICS mode the initial channel ca...

Страница 9: ...djust these switches to the desired length in 0 1 second increments position 1 0 1 seconds position 2 0 2 seconds etc see Figure 2 3 JP4 JP9 1 2 3 4 O F F ROCKER DOWN S3 ROCKER SWITCH DETAIL SHOWN WIT...

Страница 10: ...ual or Remote selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot...

Страница 11: ...he equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effec...

Страница 12: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 14 Manual_A Page 12 0...