Pg. 7
OPERATION
(Full instructions pg. 22 to 30)
!
NOTE: When starting the generator after adding
fuel for the first time or after long term storage, or after
running out of fuel, turn the fuel valve to the ON position,
then wait for 10 to 20 seconds before starting the engine.
!
NOTE: Turn on the fuel valve.
1.
Push the engine switch on the control panel to the
“ON” position (Refer to page 17).
2. Pull the choke lever out to the “START” position.
3.
Pull the starter grip lightly until resistance is felt, then
pull briskly out. Repeat until the engine starts.
4. Push the choke lever back to the “RUN” position.
5. The green “RUN” light will illuminate when the
generator is ready for use before connecting any
loads.
6.
Make sure that all appliances to be connected have
been switched off and are in good working order.
Confirm that the combined electrical rating of the
appliances does not exceed that of the generator.
7.
Connect the appliance to the appropriate receptacle
on the generator’s control panel.
8.
To minimize fuel consumption and noise, push the
economy switch to the “ON” position. This setting
regulates the engine’s speed so that it matches
the needs of the connected loads. Do not use the
economy setting if you are connecting items with
electric motors that have a high amperage draw
during startup, or with appliances that cycle on and
off rapidly.
SHUTDOWN
!
NOTE: In an emergency, pushing the engine switch on
the control panel to the “OFF” position will automatically
stop the engine with or without a load.
1. Turn off all connected appliances.
2.
Push the engine switch on the control panel to the
“OFF” position.
3.
Turn the fuel valve off.