![Cristec BAT-MON-3.5 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/cristec/bat-mon-3-5/bat-mon-3-5_user-manual_2686025032.webp)
31
5.1
B
ATTERY MODE
After pressing the circle in Battery mode the specifics battery details are shown:
•
Battery
Main battery (+1) name, voltage and current
•
Capacity
Actual capacity in percent (%)
•
Time remaining
2
Expected remaining time until the capacity alarm
triggers,or expected charging time during charging
•
Mode
Charge, discharge or Not synchronized
•
Temperature
Battery temperature when external sensor is connected
•
Battery (+2)
Additional battery (+2) name and voltage
The mode "Not synchronized" appears when the shunt is restarted and the displayed capacity value does not yet correspond
to the true capacity level. Then the battery connected to the shunt must be fully charged with a battery charger, so that the
capacity indicator can synchronize with the state of charge of the battery. The message then goes off automatically.
5.1.1
Battery records
By pressing the magnifying glass icon more detailed historic information about
the battery are shown:
•
Charging cycles
2
Number of charging cycles
•
Deep discharges
2
Number of deep discharges
•
Lost capacity
2
The lost (not useable) capacity (%)
•
Discharge rate
2
Average discharge rate
The min/max values are determined from a 45 seconds interval to get an idea
about the use of the battery
3
:
•
Max. Charge / Max. charge and discharge currents
•
Lowest / Highest voltage (+1 lead mesurement)
•
Lowest / Highest temperature (when external sensor is connected)
5.1.2
Battery history (available for shunt #1 only)
By pressing the chart symbol, the battery usage is graphically displayed.
You can access information
3
about the
last 3 hours (3h), the last 3 days (3d) and the last 30 days (30d).
History
Resolution
Content
3 hours
45 seconds
Capacity, mean voltage and average current over the last 3 hours.
3 days
18 minutes
Capacity, mean voltage and average current over the last 3 days.
30 days
3 hours
Minimum / maximum capacity and minimum / maximum voltage over
the last 30 days
2
See terms and definition in section 5.3
3
Records are lost if the display power supply is switched-off
See section 5.1.1
See section 5.2.2