Supplemental Guide – DOC. 8412A
UC-P100-S/UC-P110-S Phones for Skype for Business
•
349
Parameter
Permitted Values
Default
static.auto_provision.local_log.backup.append.max_f
ile_size
Integer from 200
to 65535
1024
Description:
Configures the maximum size (in KB) of the local log files to be stored on the provisioning server
or a specific server.
Example: static.auto_provision.local_log.backup.append.max_file_size = 1024
Web User Interface:
Settings > Configuration > Max size for backup log
Phone User Interface:
None
static.auto_provision.local_log.backup.append.limit_
mode
0 or 1
0
Description:
Configures the behavior when local log files on the provisioning server or a specific server reach
the maximum size limit.
0-
Delete, the server will delete the old log and the phone will continue to uploading log files.
1-
Stet, the phone will stop uploading log files.
Web User Interface:
Settings > Configuration > Backup limit mode
Phone User Interface:
None
static.auto_provision.local_log.backup.
bootlog.uploa d_wait_time
Integer from 1 to
86400
120
Description:
Configures the waiting time (in seconds) before the phone uploads the boot.log file to the
provisioning server or to a specific server after startup.
Example: static.auto_provision.local_log.backup.bootlog.upload_wait_time = 121
Web User Interface:
Settings > Configuration > Bootlog backup time
Phone User Interface:
None
Export the Log Files to a Local PC
Local log files can be exported to a computer via the Web User Interface. The exported
local log files include three types: boot.log, sys.log, and sipsignal.log. The sipsignal.log
appears only when the local log level is adjusted to debug and the phone receives or
sends SIP message. These three local log files can be exported via the Web User
Interface simultaneously.