12 Inch Tilt Touchpanel
Crestron Isys™
TPS-5000
Specifications for the TPS-5000 Touchpanel (continued)
SPECIFICATION DETAILS
Display Type
Touch-sensitive active matrix color LCD
Enclosure
High impact, black molded plastic enclosure
CPU
63MIPs Coldfire processor running Isys generation
firmware
Cresnet
Via TPS-IMPC (included) or optional TPS-IMW
RS-232
RJ-11 connector for console, telestrator, etc.
Default settings: 115200, 8 bit, parity none, stop
bit 1.
Operating Temperature
and Humidity
50º to 113º F (10º to 45º C),
10 to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Height: 11.86 in (30.12 cm)
Width: 13.26 in (33.69 cm)
Depth: 10.56 in (26.81 cm)
Weight: 7.64 lbs (3.46 kg)
1
The individual power requirements for the expansion cards are:
TPS-ENET: 4 Watts (0.167 Amps @ 24 VDC)
TPS-VID-1: 7 Watts (0.29 Amps @ 24 VDC)
TPS-VID-2: 12 Watts (0.50 Amps @ 24 VDC)
TPS-XVGA: 10 Watts (0.417 Amps @ 24 VDC)
2
The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com). Refer to NOTE after last footnote.
3
Crestron 2-Series control systems include the AV2, C2N-DVP4DI, CP2, CP2E, MC2E, MC2W,
MP2, MP2E, PAC2, PRO2, QM-RMC, QM-RMCRX, and RACK2.
4
CNX update files are required for either CNMSX-AV/PRO or CNRACKX/-DP. Filenames for CNX
update files have a UPZ extension and ST-CP files are in one EXE or zipped UPZ file. To avoid
program problems, make certain you are using the update file with the correct suffix letter (e.g., S,
V, W, X).
5
When loading VT Pro-e files or firmware through the RS-232 port of the control system, be sure that
the baud rate is at 38400 (Cresnet speed) or lower. Otherwise, the Viewport may post the "Transfer
Failed" message.
6
These control systems do not support loading of firmware or VT Pro-e files to the TPS-series panels
through the RS-232 port of the control system. In order to load these files to the TPS-5000 when
using these control systems, use the RS-232 port on the TPS-5000 or use a direct Ethernet
connection to the panel (assuming the TPS-ENET is installed).
7
WAV files reside in the touchpanel’s Flash memory and will affect the amount of available space for
touchpanel screens.
8
Additional Flash memory can be purchased, refer to "Memory" on page 7. The complexity of the
control screens and the sampling of the WAV files influence memory usage.
NOTE:
Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).
4
•
12 Inch Tilt Touchpanel: Crestron Isys™ TPS-5000
Operations Guide - DOC. 5863A