Crestron CPC-CAMI Скачать руководство пользователя страница 15

Crestron 

CPC-CAMI

 

Pan/Tilt Camera Head with Control Interface

 

Maintenance 

NOTE:  

Do not attempt to open the unit to make any adjustments or repairs. In the 

event that an operating problem occurs, contact a member of Crestron’s technical 
support team.  Refer to “Further Inquiries” on page 17.  

The CPC-CAMI has been designed to eliminate the need for periodic maintenance. 
Lubrication for all moving parts is permanent. Motors, switches, and other moving 
parts are rated in excess of normal expected operating life of the unit.  

Programming 

Position/Rate Mode Definition 

In position mode, a voltage corresponding to a position of the lens (focus or zoom) is 
fed to the lens interface and the lens moves the motors to the position that 
corresponds to the input voltage. In rate mode, the voltage fed to the lens 
corresponds to the rate and direction in which the motor moves. The result is smooth 
lens movement.  

Most lens types operate in rate mode. If position feedback is provided then 
focus/zoom presets can be recalled. Without feedback, lens presets cannot be 
achieved in rate mode. Some lenses can switch between rate and position mode; the 
CPC-CAMI provides the appropriate connections to facilitate this. This type of lens 
can achieve “virtual” presets without true feedback pots from the lens.  

Programming the CPC-CAMI in SIMPL 

SIMPL (Symbol Intensive Master Programming Language) is an easy-to-use 
programming language that is completely integrated and compatible with all 
Crestron system hardware. The objects that are used in SIMPL are called symbols. 
SIMPL Windows offers drag and drop functionality in a familiar Windows® 
environment.  

SIMPL Windows is Crestron Electronics’ development environment for 
programming Crestron control systems.  It provides a well-designed graphical 
environment with a number of workspaces (i.e., windows) in which a programmer 
can select, configure, program, test, and monitor a Crestron control system.  

Two sample SIMPL Windows programs are presented in this document for the two 
separate lens control configurations. The first subsystem  supports lenses that use 
CPC-CAMI jumper boards A, B, or D. The second subsystem is specific for lenses 
using CPC-CAMI jumper board C and have the separate rate/position drive. 

NOTE:

  The following description assumes that the reader has some knowledge of 

SIMPL Windows. If not, please refer to the extensive help information provided 
with the software.  

NOTE:

  The earliest version of SIMPL Windows did not have a “CPC-CAMI” 

available from the Network Control Module folder in the Device Library of SIMPL 
Windows’ Configuration Manager. When using an earlier version of SIMPL 
Windows choose “CNCAMI” from the Device Library instead. However, realize 
that the full functionality of the CPC-CAMI cannot be fully defined by the 
“CNCAMI” symbol. Crestron recommends a SIMPL Windows and operating system 
upgrade to fully implement CPC-CAMI functionality.  

Operations Guide - DOC. 5726A 

Pan/Tilt Camera Head with Control Interface:  CPC-CAMI  

  13 

Содержание CPC-CAMI

Страница 1: ......

Страница 2: ...Calibration 12 Maintenance 13 Programming 13 Position Rate Mode Definition 13 Programming the CPC CAMI in SIMPL 13 Problem Solving 17 Troubleshooting 17 Further Inquiries 17 Return and Warranty Polici...

Страница 3: ...lt in network control interface Jumper Boards Four supplied jumper boards permit the support of any camera lens assembly requiring an input voltage in the range of 2 5 to 12 VDC Thus a single CPC CAMI...

Страница 4: ...A jumper board may be selected that best accommodates the mode parameters required by the system Refer to Position Rate Mode Definition on page 13 for a more detailed explanation of position and rate...

Страница 5: ...Most 4 conductor phone cables are wired in a crisscross fashion and are not compatible with Crestron equipment The wiring document can be obtained from the Downloads page CABLES and MANUALS Libraries...

Страница 6: ...ontrol 2 12 5V to Pots 13 Pot Zoom 14 Pot Focus 15 0 Volts to Pots Wiring Diagram for Lens A B and D 12V 8V and 6V M POWER_GND IRIS_CONTROL_1 IRIS_CONTROL_2 FEEDBACK_SUPPLY_ 5V ZOOM_FEEDBACK FOCUS_FEE...

Страница 7: ...SPEED POS SIG 7 6 POWER_GND RATE POSITION 5 4 IRIS SPEED POS SIG SIGNAL COMMON V1 7 5V 10 7 11 ZOOM SPEED POS SIG 2 1 HIROSE LENSE CONNECTOR ZOOM_MOTOR POWER_GND 2 1 FOCUS CONTROL ZOOM CONTROL GROUND...

Страница 8: ...creened label Refer to the illustration shown in CPC CAMI Ports on page 3 and the descriptions after this paragraph NOTE Each set of up and down buttons provides dual function For example the upper mo...

Страница 9: ...r CRESDB Libraries of Crestron s website www crestron com New users are required to register in order to obtain access to the FTP site 2 CNX upgrade files are required for either CNMSX AV PRO or CNRAC...

Страница 10: ...to the longer side allows for a greater range of motion assuming that the CPC CAMI is directly mounted to a large horizontal surface NOTE The CPC CAMI has an identifying mark labeled FRONT on the flat...

Страница 11: ...IGHT ADJUSTMENT gap At this location tighten the two slotted pan head screws Camera Lens Mounting WIDTH CLEARANCE SOCKET HEAD SCREW 8 32 x 3 8 WITH WASHER 8 PAN PHILLIPS HEAD SCREW 1 4 20 x 3 8 ANGLED...

Страница 12: ...o 34 but may be changed from the PC via VisionTools Pro e VT Pro e or SIMPL Windows The method for changing the unit s NET ID is identical regardless of the software chosen Attach the CPC CAMI to the...

Страница 13: ...on drawing Doc 5411 Most 4 conductor phone cables are wired in a crisscross fashion and are not compatible with Crestron equipment The wiring document can be obtained from the Downloads page CABLES an...

Страница 14: ...he stop positions at slow speeds and then at full speed to ensure proper settings Calibration Over time it may be necessary to recalibrate the CPC CAMI to ensure proper operation Occasionally placing...

Страница 15: ...se programming language that is completely integrated and compatible with all Crestron system hardware The objects that are used in SIMPL are called symbols SIMPL Windows offers drag and drop function...

Страница 16: ...ple SIMPL program is shown in block diagram form below SIMPL Windows contains a couple of macros within the Crestron Modules folder which can easily control pan tilt zoom focus as well as store and re...

Страница 17: ...has to be manipulated so we can achieve virtual presets when driving the FOCUS_SET and ZOOM_SET separately via ANALOG RAMPS and a second set of focus zoom buttons While in positional mode an internal...

Страница 18: ...onless the analog level at each of these programmed outputs should be 50 If one of these levels rises higher than 50 the corresponding pan tilt axis or focus zoom lens position is adjusted in the posi...

Страница 19: ...e two or more units share the same ID Poll network in Performance Viewport Verify that each ID is used once ID setting changed after CPC CAMI powered up Power down CPC CAMI Power up to reset ID Preset...

Страница 20: ...ered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warrant...

Страница 21: ...EA 3 RED Lens Common 2 FOCUS 2 WHT Focus Motor Drive 1 8 RED BLK Feedback Supply 12 7 WHT BLK Focus Feedback 14 ZOOM 1 BLK Zoom Motor Drive 3 4 GRN Zoom Feedback 13 6 BLU Zoom Ground 15 OR Panasonic W...

Страница 22: ...grey Zoom Feedback 13 Lens Cabling Connection for Jumper D 6V CONNECTOR 8000 9801 00 4 Lens Common 2 FOCUS 3 Focus Motor Drive 1 6 Feedback Supply 12 8 Focus Feedback 14 5 Feedback Ground 15 ZOOM 2 Zo...

Страница 23: ......

Страница 24: ......

Отзывы: