background image

ONE

9

Original instructions.

· Packaging

 

The machine is shipped in a custom-designed carton which utilizes model-specific polystyrene  

 

 

cushions to protect it from damage.

  

The machine’s carton features standardized handling symbols to explain proper shipping and storage methods.

  

The machine must remain in a horizontal position during the transport. Do not store or handle the machine except on its feet.

   During transport protect the carton and machine from impact drops, crushing, shocks, moisture and exposure to extreme 

temperature.

· Delivery inspection

   Upon receipt and delivery ensure that the machine is in the exact condition described in the enclosed documentation, and that 

all accessories are included. Missing items should be reported to the manufacturer or dealer immediately.

   Damage caused during transport should be reported to the shipping agent and the machine’s distributor immediately.
  Packaging materials are potentially dangerous and should be kept away from children.
  The carton and all packing materials are recyclable and should be returned to a recycling centre   

    for disposal. 

TRANSPORT

· Long-term storage requirements

Before storage for a month or more be sure to:

• Perform all weekly and periodic cleaning procedures described in this manual.

• Disconnect and roll up the power cord (this should be performed by a qualified person).

• Disconnect the machine’s water inlet hose from the domestic water supply and drain the boilers (this should be performed by a 

qualified person).

• Clean the drip tray and exterior of the machine to remove any coffee or other residue.

• Cover / re-pack the machine in its original carton and store it in a dry place where it will not be exposed to extreme 

temperatures or humidity.

• When returning the machine to service after long-term storage, perform all weekly and periodic cleaning procedures and 

reconnect the water and power supplies (this should be performed by a qualified person) before use.

STORAGE AND DISPOSAL

· Machine disposal requirements

If the machine ever needs to be scrapped and disposed of be sure to:

•  

Disconnect and roll up the power cord (this should be performed by a qualified person).

•  Disconnect the machine’s water inlet hose from the domestic water supply and drain the boilers (this 

should be performed by a qualified person).

• 

Pack up and ship/deliver the machine to a certified recycling centre.

Plug

Region

Part No.

Description

Type F 16A

EU/KO

160570

Power_Cord_1PhN_16A_Type_F

Nema 6-20P

US/CAN

6165278

Power_Cord_UL_C19_Nema6-20P

Type G 13A

UK

1605002

Power_Cord_1PhN_13A_Type_G

Type I 10A

Aus

1605674

Power_Cord_1PhN_10A_Type_I

Nema 6-20P

China

1605001

Power_Cord_UL_C19_Nema6-20P

List of original detachable power cord by plug type:

· Caution

• 

Risk of fire and electric shock.

•  Replace only with manufacturer’s  
  original cord set.
•  Disconnect from power supply  
  before servicing.

Содержание ONE 1B VP

Страница 1: ...ONE UM_EN Part No 1964195 Rev 07 User Manual...

Страница 2: ...lling the water tank 13 Mains water connection 14 Hydraulic supply selection 14 Optimal working range 14 Water filter requirements 15 Drain connection checklist 15 Electrical connection checklist 16 I...

Страница 3: ...Manual mode Run the shot 24 Manual mode Save recipe 24 Recipe mode Choose recipe 25 Recipe mode Recipe graph information 25 Recipe mode Run the shot 25 MACHINE ALERTS 26 Alarms Warnings 26 TROUBLESHOO...

Страница 4: ...serve Important notifications to ensure food safety prevent possible minor personal injury or damage to the machine WARNING Indicates a potentially hazardous situation which if the WARNING is ignored...

Страница 5: ...properly trained to operate the machine and understand the potential risks involved The owner or installer will be liable for all non authorised modification of the machine Non authorised alteration o...

Страница 6: ...1MPa 1 Bar 14 5 psi Maximum inlet water temperature 25 C 77 F Ambient temperature between 10 C 40 F min and 40 C 104 F max IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautio...

Страница 7: ...s for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Ensure that the power supply voltage does not fluctuate by more than 6 Do not let power cord hang over...

Страница 8: ...ebyapersonresponsible fortheirsafety Childrenmustbesupervisedsotoensurethattheydonotplay withthe appliance Note safetyregulationnotvalidforEurope SpecificsafetyregulationforEurope Thisappliancecanbeus...

Страница 9: ...med by a qualified person Disconnect the machine s water inlet hose from the domestic water supply and drain the boilers this should be performed by a qualified person Clean the drip tray and exterior...

Страница 10: ...BSPP Internal thread Ambient noise 70 db ONE Compliance codes Machine ID Dispensing Control System Boiler System Group Boiler Volume Machine Weight Power Rating ONE 1B VP EAJB K91F 13BP Commercial CRE...

Страница 11: ...1 x1 I Filter basket 18 Gr x1 J Tamper x1 K Extra steam nozzle x1 L Milk Jar x1 TECHNICAL SPECIFICATIONS Machine description Pos Description 9 Brewing lever 10 Hot water tap 11 Hot water knob 12 Digit...

Страница 12: ...quiped with a pressure profiling knob 4 buttons OLED display Shot timer Temperature 1 Tank empty refill signal 2 Heating signal Shot timer Temperature Volume 2B LFPP Heating Tank empty refill Several...

Страница 13: ...ne is ready for use Filling the water tank INSTALLATION AND START UP 1 Installing the machine in the service area must be performed by a qualified person As the machine may be quite heavy at least two...

Страница 14: ...le on these models and it will work like TANK ONLY INSTALLATION AND START UP 1 Connecting the machine to the domestic water supply must be performed by a qualified person Contact a service technician...

Страница 15: ...g fittings Only use safe drinking water with a hardness rating between the parameters on the following table If the hardness value is below this limit corrosion of hydraulic components is likely If th...

Страница 16: ...urer will not be held liable for damage to persons animals or property resulting from incorrect installation of the coffee machine After carry out the machine installation follow the next steps for th...

Страница 17: ...could cause scalding or serious injury After dispensing has finished wait at least 3 seconds before removing the portafilter Pro Tip When not in use store the portafilter inserted in the group to kee...

Страница 18: ...up of coffee residue that often accumulates inside the drain cup and tube Tank Remove and clean the water tank with detergent and a soft brush if needed Rinse properly Water Tank Filter The water tan...

Страница 19: ...ser interface 1B Adjusting boiler temperature USER PROGRAMMING 2B USER PROGRAMMING 1B The ONE 2B machines are equipped with a programmable Barista interface that allows users to set or adjust the foll...

Страница 20: ...up boiler temperatures individually Group boiler figure 10 Set temperature of the group boiler Steam boiler figure 11 Set temperature of the steam boiler Use the arrows figure 6 7 to adjust each setti...

Страница 21: ...ust a few minutes when needed Stand by mode disconnects the elements completely ECO mode On Barista menu access to Heating element On Off figure 14 settings Use this function to activate ON or deactiv...

Страница 22: ...ec to reset the partial counter Pro Tip The counters can be useful for calculating the number of coffees dispensed over a day week or month which is helpful in calculating expenses when machine cleani...

Страница 23: ...back of the machine then press import figure 29 to upload the image Import recipe figure 30 Copy the desired recipes files files must be in txt format named IMPONE txt onto an empty USB stick Insert t...

Страница 24: ...ustment Default initial setting Choose the initial pressure by rotating the PP knob 2 12 Bar 2 Bar Manual mode Access Manual mode Initial PP pressure Manual mode Run the shot Manual mode Save recipe W...

Страница 25: ...ECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1 43s 6 7 8 9 10 11 cl 9 5 0 b RECIPE 1 43s 12 13 14 15 16 17 cl 9 5 0 b RECIPE 1 43s 18 19 20 21 22 23 cl 9 5 0 b K2 RECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1...

Страница 26: ...osition Error Code Alarm Name Warning Alarm Solution Steam boiler sensor AL1 Temp Probe shortcircuited AL2 Temp Probe unconnected Alarm Call a service technician to replace it Group boiler sensor AL1...

Страница 27: ...ter is found underneath the machine The drainage tube is blocked with used grounds rubbish Clean the drainage tube Problem Possible cause Solution Coffee dispensing temperature is too cold Heat exchan...

Страница 28: ...s been made and warranty claim been issued without delay The affected equipment may not be used during awaiting service if there is any risk that the damage or defect would worsen The warranty will no...