ONE
18
Original instructions.
Daily cleaning – At the end of each working day be sure to:
Steam and Hot
Water
1. Position the steam wand over the drip tray and open the steam tap for one minute to fully flush the
wand. Repeat for each steam wand.
2. Clean the steam wand and the water tap. Be sure that the nozzles are not clogged or partially blocked
with milk or other residue. If it’s necessary to remove them for cleaning, be careful not to deform or dam-
age any of the components during removal.
Group Head and
Portafilters
1. Clean the shower plate and the group gasket with a soft brush to remove and coffee residue.
2. Run the flushing cycle for each group at the end of each day to prevent coffee residue drying and build
-
ing up inside the brewing groups.
Drip Tray &
Bodyworks
1. Clean the external surfaces of the machine, paying special attention to the glass and stainless steel parts
to remove any coffee residue and smudges and fingerprints.
2. Clean the drip tray and the stainless steel insert grid under running water.
Daily flushing
1. Place the blind filter in the emptied portafilter, then lock the portafilter into the brewing group.
2. Pull up the group lever and keep the pump working for 10 sec and stop 5 sec. Repeat at least 5 times.
3. After cleaning, remember to remove the blind filter and store it in a safe place for the next usage.
4. Clean the internal side of the portafilter before replacing the espresso filter. If needed, let the portafilter
soak into warm water or use cleaning detergent for espresso machines.
WARNING
!: Do not open the group or remove the portafilter until the cleaning has finished! This will
release steam and hot water which could result in burns.
Weekly cleaning or Periodical cleaning and care – Once per week be sure to:
Group Head
Run the cleaning cycle for each group at the end of each week to thoroughly clean the group head, shower
plate and portafilter to ensure great coffee taste. See Weekly cleaning with espresso machine detergent
section for details.
Drain Hose
If the drain hose is installed, clean the drain cup by slowly pouring one liter of warm water into it to
dissolve and remove any build-up of coffee residue that often accumulates inside the drain cup and tube.
Tank
Remove and clean the water tank with detergent and a soft brush if needed. Rinse properly.
Water Tank Filter
The water tank filter must be replaced when the expiration date is reached (2 months since installation).
Use the following steps to recharge your water softener.
1. Switch the machine off and remove the top panel/cup warming tray.
2. Remove the filter from the tank and install the new one. (follow instructions from "Water filter
requirements" section.
3. Replace the top panel/cup warming tray and switch the machine on.
Water mains
filter
If an external softener is installed, follow and perform the maintenance instructions and respect the
replacing or recharging periods described by the manufacturer.
Weekly cleaning
with espresso
machine
detergent
1.
Place the blind filter in the emptied portafilter, add espresso detergent in the blind filter,
then lock the
portafilter into the brewing group.
2. Pull up the group lever and keep the pump working for 10 sec and stop 5 sec. Repeat at least 5 times.
3. After cleaning, with detergent, the group needs to be flushed. So repeat the process 2 more times to flush
out any remaining detergent. Then remove the blind filter and store it in a safe place for the next usage.
Pro Tip:
Run the cleaning cycle for each group at the end of each week to thoroughly clean the group
head, shower plate and portafilter to ensure great coffee taste.
Professional espresso machine detergent. Part no: 1104171
Cleaning reminders
To keep the machine looking and working like new, always follow all the cleaning and care instructions provided in this manual.
For safety always turn the machine off at the main power switch when cleaning the exterior surfaces.
All exterior surfaces must be cleaned with a damp, lint-free cloth that will not scratch the machine, glass surfaces can be cleaned
with a streak-free glass cleaner and a dry cloth.
Do not use aggressive cleaning detergents, solvents or degreasers. These may damage the plastic and rubber parts, and will
leave unwanted residue
WARNING
!:
Do not open the group or
remove the portafilter until the cleaning has
finished! This will release steam and hot water
which could result in burns.
Pro Tip:
To adjust the service alarms (
),
please go to the Service Manual.
(QR Cove page)
CLEANING AND CARE