background image

ONE

10

Original instructions.

· Machine data

ONE

Compliance codes

Machine ID

Dispensing

Control 

System

Boiler

System

Group

Boiler

Volume

Machine

Weight Power Rating

ONE 1B 

VP

EAEB-I91F-13AP

CREM8091

(AUS/UK/IL/CH)

Manual Group 

lever

1 steam boiler

-

30 kg

66 lb

220-240V~ 

50-60Hz 1950W

ONE 2B 

VP

EEEB-I91F-13AP

CREM8092

(AUS/UK/IL/CH)

Dual boiler:  

1 steam boiler  

+ 1 group boiler

1.5L

0.40 gal.

35 kg

77 lb

ONE 2B

RP-GSP

EEEB-I91G-13AP

CREM8093

(AUS/UK/IL/CH)

Manual Group 

lever + GSP

ONE 2B 

RP-LFPP

EEEB-I94G-13AP

CREM8094

(AUS/UK/IL/CH/

KC)

Manual Group 

lever

+ GSP + LFPP

All

versions:

Temperature control:

PID Control

Steam wand:

x1

Hot water outlet:

x1

Boiler operating pressure:

0.8 to 1.3 bar / 12-19 psi

Steam boiler volume:

1.7L / 0.45 gal.

Water connection:

3/8” BSPP Internal thread

Ambient noise:

< 70 db

ONE

Compliance codes

Machine ID

Dispensing

Control 

System

Boiler

System

Group

Boiler

Volume

Machine

Weight Power Rating

ONE 1B 

VP

EAJB-K91F-13BP

Commercial:

CREM8091US

*Domestic:

CREM8091DUS

Manual Group 

lever

1 steam boiler

-

30 kg

66 lb

Commercial:

110-127V~ 

50-60Hz 1300W

*Domestic:

110-127V~ 

50-60Hz 1400W

ONE 2B 

VP

EEJB-K91F-13BP

Commercial:

CREM8092US

*Domestic:

CREM8092DUS

Dual boiler:  

1 steam boiler  

+ 1 group boiler

1.5L

0.40 gal.

35 kg

77 lb

Commercial:

110-127V~ 

50-60Hz 1300W

*Domestic:

110-127V~ 

50-60Hz 1400W

ONE 2B

RP-GSP

EEJB-K91G-13BP

Commercial:

CREM8093US

*Domestic:

CREM8093DUS

Manual Group 

lever + GSP

Commercial:

110-127V~ 

50-60Hz 1300W

*Domestic:

110-127V~ 

50-60Hz 1400W

ONE 2B 

RP-LFPP

EEJB-K94G-13BP

Commercial:

CREM8094US

*Domestic:

CREM8094DUS

Manual Group 

lever

+ GSP + LFPP

Commercial:

110-127V~ 

50-60Hz 1300W

*Domestic:

110-127V~ 

50-60Hz 1400W

TECHNICAL SPECIFICATIONS

* Domestic models: For household use only

Содержание ONE 1B VP

Страница 1: ...ONE UM_EN Part No 1964195 Rev 07 User Manual...

Страница 2: ...lling the water tank 13 Mains water connection 14 Hydraulic supply selection 14 Optimal working range 14 Water filter requirements 15 Drain connection checklist 15 Electrical connection checklist 16 I...

Страница 3: ...Manual mode Run the shot 24 Manual mode Save recipe 24 Recipe mode Choose recipe 25 Recipe mode Recipe graph information 25 Recipe mode Run the shot 25 MACHINE ALERTS 26 Alarms Warnings 26 TROUBLESHOO...

Страница 4: ...serve Important notifications to ensure food safety prevent possible minor personal injury or damage to the machine WARNING Indicates a potentially hazardous situation which if the WARNING is ignored...

Страница 5: ...properly trained to operate the machine and understand the potential risks involved The owner or installer will be liable for all non authorised modification of the machine Non authorised alteration o...

Страница 6: ...1MPa 1 Bar 14 5 psi Maximum inlet water temperature 25 C 77 F Ambient temperature between 10 C 40 F min and 40 C 104 F max IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautio...

Страница 7: ...s for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Ensure that the power supply voltage does not fluctuate by more than 6 Do not let power cord hang over...

Страница 8: ...ebyapersonresponsible fortheirsafety Childrenmustbesupervisedsotoensurethattheydonotplay withthe appliance Note safetyregulationnotvalidforEurope SpecificsafetyregulationforEurope Thisappliancecanbeus...

Страница 9: ...med by a qualified person Disconnect the machine s water inlet hose from the domestic water supply and drain the boilers this should be performed by a qualified person Clean the drip tray and exterior...

Страница 10: ...BSPP Internal thread Ambient noise 70 db ONE Compliance codes Machine ID Dispensing Control System Boiler System Group Boiler Volume Machine Weight Power Rating ONE 1B VP EAJB K91F 13BP Commercial CRE...

Страница 11: ...1 x1 I Filter basket 18 Gr x1 J Tamper x1 K Extra steam nozzle x1 L Milk Jar x1 TECHNICAL SPECIFICATIONS Machine description Pos Description 9 Brewing lever 10 Hot water tap 11 Hot water knob 12 Digit...

Страница 12: ...quiped with a pressure profiling knob 4 buttons OLED display Shot timer Temperature 1 Tank empty refill signal 2 Heating signal Shot timer Temperature Volume 2B LFPP Heating Tank empty refill Several...

Страница 13: ...ne is ready for use Filling the water tank INSTALLATION AND START UP 1 Installing the machine in the service area must be performed by a qualified person As the machine may be quite heavy at least two...

Страница 14: ...le on these models and it will work like TANK ONLY INSTALLATION AND START UP 1 Connecting the machine to the domestic water supply must be performed by a qualified person Contact a service technician...

Страница 15: ...g fittings Only use safe drinking water with a hardness rating between the parameters on the following table If the hardness value is below this limit corrosion of hydraulic components is likely If th...

Страница 16: ...urer will not be held liable for damage to persons animals or property resulting from incorrect installation of the coffee machine After carry out the machine installation follow the next steps for th...

Страница 17: ...could cause scalding or serious injury After dispensing has finished wait at least 3 seconds before removing the portafilter Pro Tip When not in use store the portafilter inserted in the group to kee...

Страница 18: ...up of coffee residue that often accumulates inside the drain cup and tube Tank Remove and clean the water tank with detergent and a soft brush if needed Rinse properly Water Tank Filter The water tan...

Страница 19: ...ser interface 1B Adjusting boiler temperature USER PROGRAMMING 2B USER PROGRAMMING 1B The ONE 2B machines are equipped with a programmable Barista interface that allows users to set or adjust the foll...

Страница 20: ...up boiler temperatures individually Group boiler figure 10 Set temperature of the group boiler Steam boiler figure 11 Set temperature of the steam boiler Use the arrows figure 6 7 to adjust each setti...

Страница 21: ...ust a few minutes when needed Stand by mode disconnects the elements completely ECO mode On Barista menu access to Heating element On Off figure 14 settings Use this function to activate ON or deactiv...

Страница 22: ...ec to reset the partial counter Pro Tip The counters can be useful for calculating the number of coffees dispensed over a day week or month which is helpful in calculating expenses when machine cleani...

Страница 23: ...back of the machine then press import figure 29 to upload the image Import recipe figure 30 Copy the desired recipes files files must be in txt format named IMPONE txt onto an empty USB stick Insert t...

Страница 24: ...ustment Default initial setting Choose the initial pressure by rotating the PP knob 2 12 Bar 2 Bar Manual mode Access Manual mode Initial PP pressure Manual mode Run the shot Manual mode Save recipe W...

Страница 25: ...ECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1 43s 6 7 8 9 10 11 cl 9 5 0 b RECIPE 1 43s 12 13 14 15 16 17 cl 9 5 0 b RECIPE 1 43s 18 19 20 21 22 23 cl 9 5 0 b K2 RECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1...

Страница 26: ...osition Error Code Alarm Name Warning Alarm Solution Steam boiler sensor AL1 Temp Probe shortcircuited AL2 Temp Probe unconnected Alarm Call a service technician to replace it Group boiler sensor AL1...

Страница 27: ...ter is found underneath the machine The drainage tube is blocked with used grounds rubbish Clean the drainage tube Problem Possible cause Solution Coffee dispensing temperature is too cold Heat exchan...

Страница 28: ...s been made and warranty claim been issued without delay The affected equipment may not be used during awaiting service if there is any risk that the damage or defect would worsen The warranty will no...

Отзывы: