CRD-06600FF10N reference design board are given below:
•
Isolated 250 VDC
–
450 VDC output
•
Maximum output current limited to 20 A
•
Maximum output power limited to 6.6 kW (AC/DC mode)
•
Maximum power at 250 VDC output limited to 5 kW.
•
Power is limited to 3.3 kW in case of DC/AC mode.
•
Universal input voltage range.
•
Full load THD < 5%.
•
Peak efficiency > 96%.
•
Firmware controlled input under voltage/over voltage protection
•
Firmware controlled output overvoltage protection.
•
Input overcurrent and output overcurrent protection.
•
LEDs for various fault indications on the control board.
•
Toggle switch ON control board for choosing AC/DC or DC/AC mode.
•
Potentiometer ON control board to set output voltage in case of AC/DC mode
and grid current in case of DC/AC (grid connected) mode.