Error Message
Fault Description
Additional information
No Water Available
Main boiler unable to fill
up in required amount of
time.
The error will be raised if the fill operation
continues for more than 20 seconds.
However, if the machine is able to
successfully complete the fill operation
within 2 minutes then it will remove this
error. No further drinks can be taken once
this error is set.
Waste Pail Full
Waste bucket is full.
Waste bucket needs to be emptied. Once
this error is set the machine will not re-
attempt to fill the water tank until the
operator goes in and out of service menus.
Please Wait
Transition based on door
switch is in progress.
This is displayed while moving from Service
Mode to Consumer UI or from Consumer UI
to Service Mode.
No IO Comms
I/O Board went through
a reboot.
This error will be cleared by the software if
it is able to successfully reconfigure and re-
initialise the I/O board.
No IO Comms 2
VMC unable to establish
communication with the
I/O board.
This error will be cleared by the software if
it is able to successfully re-initialise the I/O
board.
No Selections Available
No selections available
on the machine.
Usually a result of incorrect machine id,
configuration id or Cup Size being set on
the machine.
All Selections Disabled
All drink selections have
been disabled
The machine is taken out of service as none
of the drinks could be dispensed.
Invalid Temperature Tank 1 Water temperature
recorded in main boiler is
way beyond operational
range (0C to 125C).
The error is normally down to a faulty
temperature probe. All hot drinks using
main boiler will be disabled. The error will
be cleared when valid temperature reading
is obtained.
Invalid Temperature Tank 2 Water temperature
recorded in pressure
boiler is way beyond
operational range (0C to
125C).
The error can be generated in the following
three scenarios:
1. Faulty Temperature probe.
2. Very fine coffee grind which is
restricting the water flow.
3. Too much coffee put in the chamber
which is restricting the water flow.
Machine will disable all CoEx® based drinks
when this error is raised. The error will be
cleared when valid temperature reading is
obtained.
Содержание Voce Media
Страница 1: ...Part Number PR15302000 Issue B Aug 2015 Technical Manual ...
Страница 8: ...VIII VOCE Media ...
Страница 12: ...4 VOCE Media Section 1 Machine Specifications ...
Страница 24: ...16 VOCE Media Section 3 How to Vend a Drink ...
Страница 70: ...62 VOCE Media Section 5 Engineer s Program ...
Страница 74: ...66 VOCE Media Section 6 Service Keypad Functions ...
Страница 80: ...72 VOCE Media Section 7 Technical Information ...
Страница 86: ...78 VOCE Media Section 9 Dispense Pipe Lengths ...
Страница 107: ...Technical Manual 99 Section 11 Electrical Electronic Diagrams A FRESH APPOACH TO VENDING 11 5 Input Circuit 1 ...
Страница 108: ...100 VOCE Media Section 11 Electrical Electronic Diagrams 11 6 Input Circuit 2 ...
Страница 109: ...Technical Manual 101 Section 11 Electrical Electronic Diagrams A FRESH APPOACH TO VENDING 11 7 Output Circuit 1 ...
Страница 110: ...102 VOCE Media Section 11 Electrical Electronic Diagrams 11 8 Output Circuit 2 ...
Страница 112: ...104 VOCE Media Section 11 Electrical Electronic Diagrams 11 10 Power Circuit B2C Machines ...
Страница 114: ...106 VOCE Media ...
Страница 115: ...Technical Manual A FRESH APPOACH TO VENDING ...