Merchant™ Operators’ Guide
Programming: Diagnostic
1810025
81
August 2009
No Monetary Device
There are no monetary devices present. The machine is still
operational.
No Monetary Device - Fatal
There are no monetary devices present. The machine will be out of
service.
Refrigeration Low Side Service
Required: Warning
The IO board has reported that the machine has re-entered defrost
too quickly. Cleared on a door close.
Refrigeration Low Side Service
Required: Fatal
The IO board has reported that the machine has re-entered defrost
too quickly. Service is required. Power cycle required to clear.
Single Card Reader Error
The card reader has reported a single error.
Snack Motor Error
The indicated selection is reporting a snack motor error. View the
individual motor detail of this selection for more information.
Sold Out Selection
The indicated selection is sold out.
Stuck Key
The main controller has detected a single stuck key.
Stuck Keys - Fatal
The main controller has detected two or more stuck keys and the
machine is out of service.
SureVend Anti Jackpot Error
SureVend has detected multiple sold out selections since the last
door closure. The Anti-Jackpot trigger is user defined.
SureVend Calibration Error
SureVend is reporting a short circuit.
SureVend Comm Error
The IO board has lost communication with SureVend. Check wiring
harnesses.
SureVend Is Blocked
SureVend is reporting a blocked sensor.
DIAGNOSTIC ERROR MESSAGES
Содержание Merchant Six 180
Страница 1: ......
Страница 7: ...Merchant Operators Guide Initial Setup 1810025 1 August 2009 FRONT EXTERIOR VIEWS ...
Страница 9: ...Merchant Operators Guide Initial Setup 1810025 3 August 2009 ALL MODELS MONETARY STANDARD ...
Страница 10: ...Initial Setup Merchant Operators Guide August 2009 4 1810025 INTERIOR VIEW ...
Страница 204: ...Program System Settings Merchant Operators Guide August 2009 198 1810025 Service ...