background image

page 5

hanging ball slot

hanging bracket tab

motor housing

safety cable

wood screw

and washer

safety cable loop

wood

ceiling

joist

canopy

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang 
your fan. Grab the fan firmly with two hands. Slide 
downrod through opening in hanging bracket and let 
hanging ball rest on the hanging bracket. Turn the 
hanging ball slot until it lines up with the hanging 
bracket tab.

WARNING

: Failure to align slot in hanging ball with tab 

in hanging bracket may result in serious injury or death.

Tip

: Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you 
once you are set on the ladder. 

Find a secure attachment point (wood ceiling joist 
highly recommended) and secure safety cable. It will be 
necessary to use a heavy duty wood screw, washer and 
lock washer (not supplied) with the safety cable loop. If 
necessary, adjust the loop at the end of the safety cable. 
The loop at the end of the safety cable should just fit 
over the threads on the wood screw. Extra cable slack 
can be left in ceiling area.

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture from 

breaker panel and be sure switch is turned to the OFF position.

CAUTION

Be sure outlet box is properly grounded and that a 

ground (

GREEN

 or Bare) wire is present.

Make sure all electrical connections comply with Local Codes or 
Ordinances and the National Electrical Code. If you are unfamiliar 
with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a 
qualified electrician.

WARNING

:  If using this fan in a 

DAMP

 location, this fan must 

be connected to a supply circuit that is protected by a Ground 
Fault Circuit Interrupter (GFCI) to reduce the risk of personal 
injury, electrical shock or death.

Note

Excess lead wire length from the fan can be cut to the desired 

length and then stripped.

When downrod is secured in place on the hanging bracket, 
electrical wiring can be 
made

 

as follows:

Connect 

BLACK

 wire from fan to 

BLACK

 wire from ceiling with 

wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from ceiling with 

wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan to 

BARE

/

GREEN

 wire from ceiling with wire connector provided.

* Wrap each wire connector separately with electrical tape as an 
extra safety measure.

black

black

white

white

black supply wire

ground

 (green

or bare)

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

[”

Wiring

” 

continued on following page

]

Содержание OV70AG

Страница 1: ...Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Installation Guide For Model OV70AG net weight of fan...

Страница 2: ...ze wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of...

Страница 3: ...kit fitter 1 piece g glass shade 1 piece h glass shade cage 1 piece i yoke cover 1 piece j blade arm 5 pieces k rubber washer 1 piece l hex nut 1 piece m finial pre attached to light kit fitter 1 pie...

Страница 4: ...towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when install...

Страница 5: ...en threading them through the downrod Refer to diagram 2 Determine the length of downrod you wish to use Thread safety cable and electrical wires through threaded end of downrod and pull extra wire sl...

Страница 6: ...fixture from breaker panel and be sure switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground GREEN or Bare wire is present Make sure all electrical co...

Страница 7: ...hanging bracket and remove screw closest to the open end of the hanging bracket Partially loosen the other screw Lift canopy to hanging bracket Place rounded part of slotted hole in canopy over loose...

Страница 8: ...ing at right Attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with the remaining blade arms Securely tighten all screws Note Tighten bla...

Страница 9: ...insert screw that was previously removed and securely tighten all 3 screws with Phillips screwdriver Install three 60 watt max candelabra base bulbs included Important When replacing bulbs please allo...

Страница 10: ...ITCHES to desired code setting Turn fan power on press and hold SET button on back of remote control and on wall control for 5 seconds within 60 seconds of powering fan in order to synchronize with fa...

Страница 11: ...of the functions of the fan and light battery has been installed correctly If fan and or light do does not function please refer to Troubleshooting section to solve any issues Fan must be on LOW befor...

Страница 12: ...port 1 800 486 4892 to request one 2 Check to be sure set screw s on motor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is tightened securely Warranty WARNING Fa...

Страница 13: ...El activar el c digo P g 9 Verificaci n del funcionamiento del ventilador P g 10 Localizaci n de fallas P g 11 Garant a P g 11 Piezas de repuesto P g 11 peso neto del ventilador 13 7 kg 30 2 lb IMPRES...

Страница 14: ...sta para informarse sobre el tama o correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar HUMEDO hay que conectar el ventilador a un circuito de a...

Страница 15: ...ad d tubo de15 24cm 1 unidad e bastidor del motor 1 unidad f conectador para el juego de luz 1 unidad g pantalla de vidrio 1 unidad h caja de la pantalla de vidrio 1 unidad i cubierta del cuello 1 uni...

Страница 16: ...ginales las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia...

Страница 17: ...del cuello la tapa de la cubierta decorativa y la cubierta decorativa por el tubo Referirse al diagrama 3 Nota Se tiene que voltear la tapa de la cubierta decorativa para que el lado brillante d al ba...

Страница 18: ...laci n el ctrica ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO PRECAUCION Asegurarse...

Страница 19: ...e NEGRO del control de pared al cable principal NEGRO caliente de la casa Conectar el segundo cable NEGRO del control de pared al cable de carga NEGRO del ventilador Sujetar el control de pared a la c...

Страница 20: ...las de seguridad y los tornillos para el brazo para el aspa Antes de apretar los tornillos bien repetir el mismo procedimiento con los dem s brazos para las aspas Apretar bien todos los tornillos Nota...

Страница 21: ...con un clic Alinear los agujeros con ranura el conectador para el juego de luz con los tornillos aflojados en la placa del motor Girar para cerrarlo Volver a introducir el tornillo que se quit anteri...

Страница 22: ...del ventilador oprimir y mantener sujeto el bot n SET que se encuentra en la parte trasera del control remoto y en el control de pared por 5 segundos dentro de 60 segundos de haber conectado la elect...

Страница 23: ...reductor de luz oprimiendo el bot n y mantenerlo oprimido Si el control remoto maneja todas las funciones de ventilador y luz se ha instalado bien la bater a Si el ventilador y o la luz no funciona n...

Страница 24: ...digo Desconectar la electricidad y repetir las instrucciones en la secci n 10 p gina 9 que tienen que ver con el bot n SET Problema El ventilador se tambalea Soluciones 1 Usar el juego para balancear...

Отзывы: