background image

SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel 

before you begin the fan installation or before servicing the fan or installing accessories.

1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE 

THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different colors 
than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven 

(7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be mounted so that 
the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 

pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only CUL 
(Canada) or UL (USA) listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for 

Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet boxes 
commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced.  
Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 
gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an electrician for the 
proper size wire connectors to use.

WARNING

:  If using this fan in a DAMP location, this fan must be connected to a supply circuit that is protected by a 

Ground Fault Circuit Interrupter (GFCI) to reduce the risk of personal injury, electrical shock or death.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CUL (Canada) 
 

  or UL (USA) listed and marked suitable for use with the model fan you are installing.  Switches must be  CUL 

(Canada) or UL (USA) general use switches.  Refer to the instructions packaged with the light kits and switches for 
proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the 

outlet box.  The wires should be spread apart with the grounded conductor and the equipment-grounding 
conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or 

control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud 
humming noise from fan.] 

8.        Do not operate the reverse switch until the fan has come to a complete stop. [

Note

: If using remote control  

           

with reverse capability, reverse fan blade direction 

only

 when on LOW speed.]

 9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do not 

insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning 

the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will 

be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 than 

those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible 

conditions and situations that may occur.  It must be understood that common sense and caution are necessary factors in 
the installation and operation of this fan.

Содержание OV70AG

Страница 1: ...Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Installation Guide For Model OV70AG net weight of fan...

Страница 2: ...ze wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of...

Страница 3: ...kit fitter 1 piece g glass shade 1 piece h glass shade cage 1 piece i yoke cover 1 piece j blade arm 5 pieces k rubber washer 1 piece l hex nut 1 piece m finial pre attached to light kit fitter 1 pie...

Страница 4: ...towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when install...

Страница 5: ...en threading them through the downrod Refer to diagram 2 Determine the length of downrod you wish to use Thread safety cable and electrical wires through threaded end of downrod and pull extra wire sl...

Страница 6: ...fixture from breaker panel and be sure switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground GREEN or Bare wire is present Make sure all electrical co...

Страница 7: ...hanging bracket and remove screw closest to the open end of the hanging bracket Partially loosen the other screw Lift canopy to hanging bracket Place rounded part of slotted hole in canopy over loose...

Страница 8: ...ing at right Attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with the remaining blade arms Securely tighten all screws Note Tighten bla...

Страница 9: ...insert screw that was previously removed and securely tighten all 3 screws with Phillips screwdriver Install three 60 watt max candelabra base bulbs included Important When replacing bulbs please allo...

Страница 10: ...ITCHES to desired code setting Turn fan power on press and hold SET button on back of remote control and on wall control for 5 seconds within 60 seconds of powering fan in order to synchronize with fa...

Страница 11: ...of the functions of the fan and light battery has been installed correctly If fan and or light do does not function please refer to Troubleshooting section to solve any issues Fan must be on LOW befor...

Страница 12: ...port 1 800 486 4892 to request one 2 Check to be sure set screw s on motor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is tightened securely Warranty WARNING Fa...

Страница 13: ...El activar el c digo P g 9 Verificaci n del funcionamiento del ventilador P g 10 Localizaci n de fallas P g 11 Garant a P g 11 Piezas de repuesto P g 11 peso neto del ventilador 13 7 kg 30 2 lb IMPRES...

Страница 14: ...sta para informarse sobre el tama o correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar HUMEDO hay que conectar el ventilador a un circuito de a...

Страница 15: ...ad d tubo de15 24cm 1 unidad e bastidor del motor 1 unidad f conectador para el juego de luz 1 unidad g pantalla de vidrio 1 unidad h caja de la pantalla de vidrio 1 unidad i cubierta del cuello 1 uni...

Страница 16: ...ginales las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia...

Страница 17: ...del cuello la tapa de la cubierta decorativa y la cubierta decorativa por el tubo Referirse al diagrama 3 Nota Se tiene que voltear la tapa de la cubierta decorativa para que el lado brillante d al ba...

Страница 18: ...laci n el ctrica ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO PRECAUCION Asegurarse...

Страница 19: ...e NEGRO del control de pared al cable principal NEGRO caliente de la casa Conectar el segundo cable NEGRO del control de pared al cable de carga NEGRO del ventilador Sujetar el control de pared a la c...

Страница 20: ...las de seguridad y los tornillos para el brazo para el aspa Antes de apretar los tornillos bien repetir el mismo procedimiento con los dem s brazos para las aspas Apretar bien todos los tornillos Nota...

Страница 21: ...con un clic Alinear los agujeros con ranura el conectador para el juego de luz con los tornillos aflojados en la placa del motor Girar para cerrarlo Volver a introducir el tornillo que se quit anteri...

Страница 22: ...del ventilador oprimir y mantener sujeto el bot n SET que se encuentra en la parte trasera del control remoto y en el control de pared por 5 segundos dentro de 60 segundos de haber conectado la elect...

Страница 23: ...reductor de luz oprimiendo el bot n y mantenerlo oprimido Si el control remoto maneja todas las funciones de ventilador y luz se ha instalado bien la bater a Si el ventilador y o la luz no funciona n...

Страница 24: ...digo Desconectar la electricidad y repetir las instrucciones en la secci n 10 p gina 9 que tienen que ver con el bot n SET Problema El ventilador se tambalea Soluciones 1 Usar el juego para balancear...

Отзывы: