background image

Ground

Black

White

White

Green

Optional Light

Black

Blue

Light Switch

Figure B

17

Electrical Connections

Connect black and blue (if provided) fan wires to black outlet wire. Connect
white fan wire to white outlet wire and green grounding lead wire from the
grounding conductor to the supply circuit (see figure A). Use wire connectors
provided with your fan. No loose strands or loose connections should be
present. After wires have been connected, they must be spread apart so the
green and white are on one side of the outlet box and the black and blue
are on the other side. Turn
splices upward and carefully
push all wiring into outlet
box. For optional wall
control see figure B or
Figure C for alternate wiring.
When wall switches are employed,
switches should be UL listed
for use with ceiling fan.

NOTE:

 Make sure fan on/off switch

is always at "high speed" location if
your fan is controlled by additional
wall switch.

Ground

Black

White

Blue

Black

White

Green

Optional Light

Figure A

Operation Instructions

1. The  sequence of operation for the motor pull/chain switch is OFF-HI-

MED-LOW.

2. Push the slide switch RIGHT for FORWARD, and LEFT for REVERSE

action of the blades.

3. The pull chain switch for the lighting is two positions - ON/OFF.
4. The pull chain switch for the uplighting is on/off. 

NOTE: 

Uplighting takes

3-60W Candelabra bulbs (not included).

16

CAUTION

Even if your fan is mounted with the blades more than 7 feet from the floor, be
careful to avoid placing your raised arms or any object in the path of the blades.

Motor Pull Chain

Light Pull Chain

Slide Switch

Uplight Pull Chain

Screws

Switch Hub

Remove Switch Hub

15

Optional Light Kit Installation

The Wellington light kit is a hub-replacement type light kit. First remove
the hub from the fan by removing the four side screws and unsnapping the
wire harness. Install the Wellington hub-type light kit (WF1 OR WLK1
FOR TCS) - (WF2 OR WLK2 FOR P/C) by connecting the harness and
securing the light kit to the fan by reinstalling the four side screws removed
earlier.

All manuals and user guides at all-guides.com

Содержание K11061

Страница 1: ...19 EE UU de 8 heures 17 heures Heure standard du centre Num ro de t l copieur gratuit 877 304 1728 Email customerservice craftmade com www craftmade com P O Box 1037 650 S Royal Lane Suite 100 Coppell...

Страница 2: ...nded conductor to be connected to grounded of power supply conductor of a fan identified as ungrounded conductor to ed to an ungrounded conductor of power supply conductor of fan identified ent ground...

Страница 3: ...11 into ceiling outlet box as a secondary support means Secure mounting bracket 1 to the outlet box A by tightening bracket screws washers S3 as shown If not mounting to an outlet box use wood screws...

Страница 4: ...ghten set screw A against downrod ive cover 4 to the top of the fan motor 5 with the three over screws S9 Tighten screws firmly In addition slide the cap 11 over the downrod and snap into decor cover...

Страница 5: ...ox Fan wires Black Black Hot wire for fan Green Green Ground wire White White Neutral wire Black Blue Light kit wire Step 9 ecurity attach safety cable from fan unit to J hook S11 in Secure by looping...

Страница 6: ...1 To install the Switch Housing Assembly 9 locate both modular wiring plugs A and B One extends from the mounting plate E on bottom of fan body and one extends from the Switch Housing 9 Align the two...

Страница 7: ...speed location if your fan is controlled by additional wall switch Ground Black White Blue Black White Green Optional Light Figure A Operation Instructions uence of operation for the motor pull chain...

Страница 8: ...le speed type Fan Wobbles 1 Check that all blades are screwed firmly into blade holders 2 Check that all blade holders are screwed firmly into motor 3 Check the weight of blades All our blades are wei...

Страница 9: ...tor de un ventilador o como conductor sin tierra debe conectarse a un conductor sin tierra del de alimentaci n el conductor de un ventilador identificado para conectar quipo debe conectarse a un condu...

Страница 10: ...ure el soporte de montaje 1 a la caja de salida A apretando los tornillos del soporte y las arandelas S3 como se muestra Si no se monta en una caja de salida use tornillos para madera S1 y arandelas S...

Страница 11: ...el agujero en la misma quede alineado o en el acoplamiento del motor Inserte el perno de seguridad S7 miento y la vara hacia abajo e instale la tuerca Apriete bien Apriete fijaci n A contra la vara h...

Страница 12: ...erde Azul Negro Alimentaci n Tierra de la vara hacia abajo Verde Tierra del soporte de montaje Verde Tierra de la caja de salida Verde Paso 9 seguridad instale un lazo de alambre de acero desde el ven...

Страница 13: ...ga Apriete los tornillos firmemente 14 Paso 14 1 Para instalar el ensamblaje de la caja del interruptor 9 ubique ambos enchufes modulares de cableado A y B Uno se extiende desde la placa de montaje E...

Страница 14: ...uz deslizante trol para la acia arriba 17 Verde Tierra Negro Blanco Blanco Luz opcional Negro Azul Interruptor de luz Figura B Conexiones el ctricas Conecte los cables negro y azul si se incluyen al c...

Страница 15: ...correctamente instalados y apretados 4 Si se usa el control de pared revise que no sea del tipo transformador o de velocidad variable El ventilador se balancea 1 Revise que todas las aspas est n atorn...

Страница 16: ...masse du ventilateur doit sur le conducteur non mis la masse de l alimentation lectrique Le u ventilateur destin la mise la masse de l quipement doit tre connect eur de mise la masse de l quipement r...

Страница 17: ...pour qu il serve de dispositif de soutien suppl mentaire Fixez le support de montage n 1 la bo te de sortie A en resserrant les vis S3 et les rondelles S4 de support de la mani re illustr e Si vous n...

Страница 18: ...la vis de contre la tige de suspension Ajoutez le couvre bride n 4 du moteur du ventilateur n 5 l aide des trois vis d coratives fermement les vis Faites ensuite glisser la calotte d corative n ge et...

Страница 19: ...terre Blanc Blanc Fil neutre Noir Bleu Fil du kit d clairage Fils de connexion tape 9 e s curit attachez le c ble de s curit du ventilateur au crochet 1 accroch dans la bo te de sortie Fixez l instal...

Страница 20: ...14 1 Pour installer l assemblage de bo tier d interrupteur n 9 rep rez les prises de c blage modulaire A et B L une d entre elles sort de la plaque de montage E au bas du corps du ventilateur et l aut...

Страница 21: ...lisser l interrupteur vers la DROITE pour faire tourner le ventilateur EN AVANT ou faites le glisser vers la GAUCHE pour faire tourner les pales dans l autre sens 3 La cha ne de traction interrupteur...

Страница 22: ...tion lectrique et v rifiez tous les connecteurs 3 V rifiez les interrupteurs on off ainsi que l interrupteur de commande mural Consultez le mode d emploi Probl me B Le ventilateur fait trop de bruit S...

Отзывы: