3. Installation Preparation.
4. Mounting Plate Installation.
page 3
ON
OFF
ON
OFF
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING:
Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box, be sure
the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION:
Be sure outlet box is properly grounded and
that a ground (
GREEN
or bare) wire is present.
Locate motor mounting nuts and flat washers on
underside of mounting plate. Remove 4 motor
mounting nuts and flat washers from bolts on
mounting plate--
save for later use.
motor
mounting
nut
mounting plate
flat
washer
This fan can be mounted
only
as a
flushmount
on a regular ceiling.
Downrod
installations are
not
available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
downrod
installation
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
12f
t.
- 20f
t.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
7 feet
(2.13m) (76cm)
30
inches
blade edge
bolt