3. Installation Preparation.
page 3
4. Hanging Bracket/Mounting Plate Installation.
WARNING:
Due to the weight of this fan, it may be necessary to seek
the help of another person during installation. Installation may also be
easier if blade arms are removed. If you decide to remove blade arms,
follow the instructions in the first paragraph of step 6.
Turn off circuit breakers to current fixture from breaker panel and
be sure operating light switch is turned to the OFF position.
WARNING:
Failure to disconnect power supply prior to installation
may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box, be sure the outlet box is
securely attached to the building structure and can support the full
weight of the fan. Ensure outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved outlet box. Failure
to do so can result in serious injury.
CAUTION
: Be sure outlet box is grounded and that a ground wire
(
GREEN
or bare) is present.
For installation WITH DOWNROD,
install hanging bracket to outlet
box using original screws, spring washers and flat washers provided
with new or original outlet box.
*
If installing on a vaulted ceiling,
face opening of hanging bracket towards high point of ceiling.
Arrange electrical wiring around the back of the hanging bracket
and away from the hanging bracket opening. Continue to section 5
on page 4.
["Hanging Bracket/Mounting Plate Installation" continued on
next page.]
ON
OFF
ON
OFF
Vaulted ceiling
angle is not to
exceed 25 degrees.
downrod
installation
flushmount
installation
12f
t.
- 20f
t.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
blade edge
7 feet
(2.13m)
(76cm)
30
inches
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400 square
feet (37.2 square meters).
This fan can be mounted with a
downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by purchasing
a longer downrod (0.5in/1.27cm diameter).
After installing
hanging bracket
,
c
ontinue to
Section 5 on page 4 for those instructions.
This
fan can also be mounted as a
flushmount
only
on a regular (no-slope) ceiling.
After installing
mounting plate
, continue to Section 6 on page 6
for those instructions.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
hanging bracket
outlet box screws
flat washers
spring washers