SELF RECYCLING
Internal Flushing procedure
Choose the accessory functions menu in
the main page.
Select
SELF RECYCLING
and press
ENTER
Follow the instructions on screen
When replacing the new oil bottle, the
oil lines Must be cleaned as well
Connect the HP and LP quick couplings
through the recycling coupler. Open the
quick couplings by turning them clockwise.
Set the RECYCLING phase time and set the
vacuum time and the vacuum test time.
Press
ENTER
to start the internal flushing.
Follow the instructions
NOTE:
if the quick couplings have not been
opened yet, the unit will display a warning
You are asked to close the quick couplings
(Turn counterclockwise). The unit recovers
the gas left in the hoses and ends the cycle
Couple HP and LP
hoses together
Replace NEW
OIL
bottle