WEIGHTTEST
Testing procedure of the weighing scales
Choose the accessory functions menu in
the main page.
Choose
WEIGHT TEST
and press
ENTER.
The data on the left side show the
measured weight of the sample (gas tank
and oil scales), the data on the right the
analogue and digital values currently
read.
To perform the weight test, you need a
sample weight (4, 5 or 6 Kg for the gas tank
cell, 100-200 g for the oil scale)
or the calibration kit code
CSACAL.
After having hooked the sample weights to
the cell, the measured data must
correspond to the sample weights.
NOTE
: the above procedure is carried out to control the efficiency of the scales. To calibrate the scales,
please refer to the specific service instructions.
Gas tank scale
Oil bottles scale
Scale calibration
kit code
CSACAL
Hook sample
weight to the
load cell.