O
PERATION
5-8
D
OC
.01040086
R
EV
.7
5.3.4 Main
Control
Keys
The main control keys are defined in Table 5-3. They are used to control the basic function of the
Indoor SSPA.
Table 5-3. Main Control Keys and Function
Key Description
TRANSMIT
If the control point is local, a transmit command will be sent
to the SSPA. In remote mode this key will bring up the
SETUP (1/5) where the user can set amplifier in local mode.
STANDBY
If the control point is local, a standby command will be sent
to the SSPA. In remote mode this key will bring up the
SETUP (1/5) where the user can set amplifier in local mode.
RESET
Resets the fault state of the Amplifier. In remote mode this
key will bring up the SETUP (1/5) where the user can set
amplifier in local mode.
5.3.5 Menu
Key
Press MENU and use the directional keys to scroll through menus. To enter a menu use the
ENTER key. The EVENT LOG, SETUP, CALIBRATION, TRIP POINTS, SCREEN CFG,
VERSION, SWITCH, TIME, and IP SETUP may be changed or viewed or saved in the menu
screens by using the directional keys and enter key. To return to the main screen press MENU.
Figure 5-6 is a screen shot of the menu.
Figure 5-6. MENU Display
5.3.5.1 Event
Log
The event log can hold up to 2000 events in battery backed SRAM. After the log is full, the
oldest record will be overwritten by the newest event.
Each event logged stores the event trigger type, current operating mode, the time and date
stamp, and the following meter readings: RF Power Out, Reflected RF Power, Attenuation
Setting, Brick Hot Spot Temperature, Drain Current, Drain Voltage and Fan Speed Setting, Fan
Speed, Inlet Air Temperature, PSU Fet Temperature and PSU Diode temperature.
Содержание S4UIA
Страница 4: ...INDOOR SSPA IV DOC 01040042 REV 6 This page is intentionally left blank...
Страница 23: ...UNPACKING INSTALLATION DOC 01040044 REV 6 2 7 Figure 2 1 Connector Locations C band shown...
Страница 42: ...INITIAL POWER ON CHECKOUT 4 10 DOC 01040053 REV 6 This page is intentionally left blank...
Страница 52: ...OPERATION 5 10 DOC 01040086 REV 7 Figure 5 8 Setup 1 5 Figure 5 9 Setup 2 5 Figure 5 10 Setup 3 5...
Страница 66: ...OPERATION 5 24 DOC 01040086 REV 7 This page is intentionally left blank...
Страница 80: ...SSPA FUNCTIONAL TREE 7 2 DOC 01040089 REV 4 This page is intentionally left blank...
Страница 90: ...CUSTOMER WARRANTY AND SUPPORT A 2 APP 01040025 REV 1 This page is intentionally left blank...