ADVANCED MENU
~
22
~
4) LS (Level of Sensitivity)
“LS” is to set the sensitivity of comparing two different images. The smaller the value is, the higher sensitivity for
motion detection. The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default value is 07.
5) SS (Spatial Sensitivity)
“SS” is to set the sensitivity for detecting the size of one object (the number of the grids) on the screen. The
smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 03.
Note: The default setting of SS is 03, which means once an object is detected more than 3 grids, the
system will get triggered. So the value of SS must be less than the number of grids that you set
up for the motion detection area.
6) TS (Time of Sensitivity)
“TS” is to set the sensitivity regarding how long one object stays in the detection area and triggers the recording.
The smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 02.
7) RE (Reference)
“RE” is to set a reference for detection. The default value is 10, which means the DVR will compare the 1
st
image
and the 10
th
image according to the sensitivity of LS, SS, TS simultaneously.
The bigger the value is, the higher sensitivity for motion detection. The highest sensitivity is 61.
8) ALARM
Select N.C. (Normally Closed) / N.O. (Normally open) / OFF for the alarm polarity. The default alarm value is OFF.
7.3 REMOTE
In this menu list, you can set up remote devices to work properly.
Move to “REMOTE”, and press ”ENTER”. You will see a similar screen as the following:
ADVANCE
REMOTE
CAMERA
TITLE
DEVICE ID
PROTOCOL
RATE
DETECTION
CH1 PTZ
000 P-D
2400
REMOTE
CH2
CAMERA
000
NORMAL
2400
DISPLAY
CH3 CAMERA
000
NORMAL 2400
ALERT CH4
CAMERA
000
NORMAL 2400
SYSTEM
NETWORK
PLEASE CONSULT YOUR INSTALLER FOR ADVANCE SETTING
BACKUP
uv
SELECT
s
BACK
t
NEXT
ENTER
HDD INFO
EVENT SEARCH
EVENT LOG
The submenu items are described below:
1) TITLE
Show the camera title of each channel set in “CAMERA”.
2) DEVICE
Select the device type (CAMERA / PTZ) according to the connected camera for each channel.
3) ID
Set the ID number (0 ~ 255) for a PTZ camera.
After connecting to a PTZ camera correctly, the default ID of the PTZ camera will be shown on the screen.
4) PROTOCOL
Select NORMAL (our protocol) or P-D (PELCO-D) protocol.