LP Tank Filling
-
Use only licensed and experienced dealers.
-
LP dealer must purged tank before filling.
-
Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank
will vary by temperature.
-
A frosty regulator indicates gas overfill. Immediately close LP tank valve and call local LP gas
dealer for assistance.
-
Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
-
To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.
Check the telephone directory under “Gas companies” for nearest certified LP dealers.
LP Tank Exchange
-
Exchange your Type 1 cylinder with OPD safety feature-equipped ONLY.
-
Always keep new and exchanged LP tanks in upright position during use, transit or storage. Leak
test new and exchanged LP tanks BEFORE connecting to grill.
Large Capacity Propane Tanks and Homes:
•
LP (Liquid Propane) Coyote Grills can be installed into propane fueled houses. Meaning that if
your entire house is plumbed for propane and you have an exterior connection for such use,
then a standard LP grill from Coyote will meet your needs, regardless of the size. Any appliance
can be installed if installed properly! That is the Coyote way!
o
Coyote does not supply any gas fittings or lines, other than the regulator needed within
the grill box
o
All Coyote LP Grills come with a 20lb tank regulator. This regulator can not be used or
modified to work on any other setup.
If you are running off of a large capacity tank (more than 20lbs), then an “in-line”
LP regulator is needed, Coyote Customer Service must be contacted to assist
with this situation.
o
As counties vary from state to state, it is upon the owner/installer to ensure that all
county, state and federal codes are followed for any gas installation.
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill
is manufactured for.
This natural gas grill is designed to operate on natural gas ONLY, at a pressure regulated at 4”
(101.6mm) water column (W.C.) when equipped with the correct natural gas orifices on the valves and
a natural gas regulator on the supply line regulated at the residential meter.
IMPORTANT:
Never connect the grill to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company
representative.