All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use
pipe sealant on flare fittings.
•
The installation of this appliance must conform with local codes or, in the absence of local
codes, with either National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the
Standard for Recreational Vehicles, ANSI A 119.2/ NFPA 1192M, and CSA Z240 RV Series,
Recreational Vehicle Code, as applicable.
WARNING:
Gas valves are preset at the factory to operate on LP or natural gas. If you wish to
convert, be sure to contact your grill dealer FIRST!
This propane gas grill is designed to operate on propane gas ONLY, at a pressure regulated at 11”
(279.4mm) water column (W.C.) when equipped with the correct propane orifices on the valves and a
propane regulator on the supply line regulated at the residential meter. The LP gas grill is designed to
be used with a standard 20 lbs gas cylinder and must be constructed and marked in accordance with
specifications of the US Department of Transportation for propane gas cylinders.
Always keep cylinder securely fastened in an upright position. Never connect an unregulated propane
gas cylinder to the grill.
Do not subject propane cylinders to excessive heat.
CAUTION:
Never store a LP gas cylinder inside a building or in the vicinity of any gas-burning
appliance.
Cylinder Specifications
-
Any L.P. gas supply cylinder used with this grill must be approximately 12 inches diameter and 18
inches high. The maximum fuel capacity is 80% and is approximately
20 pounds of propane.
-
The L.P. cylinder must have a shut-off valve (see picture) terminating
in a Type 1 L.P.
-
A Type 1 compatible cylinder with a Type 1 cylinder valve has a
back-check valve which does not permit gas flow, until a positive seal
has been obtained.
-
The cylinder must be arranged for vapor withdrawal. It must also
include a collar to protect the cylinder valve. A safety relief device
having direct communication with the vapor space of cylinder must be
provided. This will expel high pressure gas if the cylinder is overfilled
or overheated which could result in fire or explosion.
-
All L.P. gas cylinders used with this appliance shall be constructed and marked in accordance with
the specifications for L.P. gas cylinders of the U. S. Department of Transportation (DOT) or the
National Standard of Canada, CAN/CSA-B339
, Cylinders, Spheres and Tubes for Transportation
of Dangerous Goods; and Commission, as applicable; and shall be provided with a listed overfilling
LP Gas Hook-up