CountyLine CL100 1 HP Скачать руководство пользователя страница 8

1.  Thread 1-1/4" close nipple into 

foot valve. Thread the other 
end of 1-1/4" close nipple into 
bottom of deep well ejector. Hand 
tighten, then tighten 1/4 turn with 
pipe wrench.

2.  The ejector has two holes in 

the top of it. Confirm nozzle is 
installed. Thread deep well venturi 
tube (longer tube) into larger 
hole until snug. Thread 1" x 5" 
nipple into smaller hole. Only 
hand tighten venturi tube. Hand 
tighten nipple 1/4 turn with pipe/ 
crescent wrench.

3.  Thread a 1-1/4" male PVC 

adapter over the venturi tube 
and into ejector. Thread a 1" 
female PVC adapter onto the 
1" x 5" nipple. Hand tighten 
adapters 1/4 turn with pipe/
crescent wrench.

4.  Subtract five feet from the 

depth of your well. This is the 
total length of PVC pipe and 
couplings to cement onto both 
1-1/4" male and 1" female PVC 
adapters. Cement a section of 
PVC pipe to each adapter, then 
lower the whole assembly into 
the well, foot valve first. Firmly clamp the end of 
the PVC pipes with a pipe clamp to prevent the 
assembly from sliding down into well.

5.  Cement as many 

couplings and 
sections of rigid 
PVC pipe on both 
the pressure and 
delivery sides as 
it takes to equal 
the depth of your 
well minus four 
feet, then firmly 
clamp the assembly 
with a pipe clamp 
to prevent the 
assembly from 
sliding down into 
the well. Be sure to 
keep track of which 
pipe is the pressure 
pipe and which is 
the delivery pipe.

To Install a Deep Well Pump

(CL520, CL100, 4" or Larger Diameter Cased Well)
For wells more than 25, but not exceeding 70 feet 
in depth, the 1 HP convertible deep well pump is 
recommended. However, the 1/2 HP deep well pump 
may also be used for depths not exceeding 70 feet.
General materials needed for the convertible pumps:
•  One can PVC cement (read instructions carefully)
•  One roll PTFE pipe thread sealant tape
•  Two 1" female PVC adapters
•  Enough rigid 1-1/4" and 1" PVC pipe and couplings 

to reach from bottom of well to pump (delivery pipe)

•  One 1-1/4" PVC elbow
•  One 1-1/4" male PVC adapter
•  One pressure regulator kit (includes fittings, tubing, 

and 1/4" plug)

•  One pressure gauge
•  Two male 3/4" PVC adapters

•  Enough rigid 3/4" PVC pipe to reach from pump to 

pressure tank to service line

•  Tank tee (for diaphragm pressure tanks)
•  Two 1/4" plugs
•  One 1/2" drain cock
In addition to General Materials for Deep Well Pumps
•  One 1-1/4" foot valve
•  One 1-1/4" close nipple
•  One ejector
•  One 1" x 5" nipple
•  One 1-1/4" female adapter
•  One well seal
•  Enough rigid 1" PVC pipe and couplings to reach 

from bottom of well to pump (pressure pipe)

•  One 1" PVC elbow
•  Two 1-1/4" male PVC adapters
•  One 1" x 4" nipple

Reminder: All joints and connections must be airtight . A single pinhole leak will prevent the proper operation of 
the pump . Use thread compound on all threaded connections unless specified otherwise .

1-1/4"

CLOSE

NIPPLE

EJECTOR

FOOT

VALVE

1" FEMALE

PVC

ADAPTER

1-1/4" MALE

PVC

ADAPTER

1" FEMALE

PVC

ADAPTER

1-1/4" MALE

PVC

ADAPTER

6392 0211

Ejector

Nozzle

Venturi

1" x 5" 

Nipple

To Household

Water System

Pump Priming

Tee with Plug

or Gauge

Not

to

Scale

1862 0205 SWJ

10'

Min.

5–10'

Suction Pipe

From Well

Foot

Valve

Priming

Tee and

Plug

Sanitary

Well Seal

Check

Valve

Installation 8

Содержание CL100 1 HP

Страница 1: ...Poco Profundo CLTS5 1 2 HP CLTS10 1 HP Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para...

Страница 2: ...ump If in doubt consult a qualified electrician General Safety Risk of burns Do not touch an operating motor Motors are designed to operate at high temperatures To avoid burns when servicing pump allo...

Страница 3: ...plications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contam...

Страница 4: ...mp from power before servicing or handling pump Remove the cover from the pressure switch Connect the bare copper ground to the ground screw in the pressure switch Connect the power supply to the term...

Страница 5: ...ow Well Pump For wells 25 feet or less in depth the 1 2 HP CLTS5 and 1 HP CLTS10 pumps are recommended However the 1 2 HP CL520 and 1 HP CL100 convertible pumps may be adapted to shallow wells with an...

Страница 6: ...pe needed to connect the PVC elbow to the 1 1 4 male PVC adapter in the front of the pump 11 Apply 2 3 wraps of PTFE tape to the male threads on the discharge tee Using pipe wrench thread 1 discharge...

Страница 7: ...on Materials needed in addition to Shallow Well General Materials for Well Points only Enough galvanized 1 1 4 pipe and drive couplings to reach from bottom of well to one foot above ground level One...

Страница 8: ...than 25 but not exceeding 70 feet in depth the 1 HP convertible deep well pump is recommended However the 1 2 HP deep well pump may also be used for depths not exceeding 70 feet General materials need...

Страница 9: ...tions to the pump itself Do not use pipe joint compounds on plastic pumps they can react with the plastic in pump components Make sure that all pipe joints in the suction pipe are air tight as well as...

Страница 10: ...tions included with the Packer jet kit Maintenance Draining for Servicing or for Winter The pump should be drained before it is disconnected for servicing or if it is in danger of freezing To drain Re...

Страница 11: ...strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well setup to deliver water A deep wel...

Страница 12: ...1 3 12 3 13 14 Overhaul Kit Deep well Ref No 1A 2 4 5 8 9 10 11 12 Ejector Kit Deep well Ref No 6 2 7 13 5 14 2 16 17 18 2 19 2 Pump Body Assembly 313 Ref No 2 6 10 15 16 1 4 NPT Plug 2 1 2 NPT Plug P...

Страница 13: ...est n dise ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier compon...

Страница 14: ...de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bombas cloacales que hay...

Страница 15: ...rta del interruptor de presi n Conecte el conductor de cobre sin revestimiento al tornillo de conexi n a tierra en el interruptor de presi n Conecte el suministro el ctrico a las terminales con la pal...

Страница 16: ...cordatorio Todas las juntas y conexiones deber n ser herm ticas Una nica fuga del tama o de un orificio de alfiler evitar el funcionamiento adecuado de la bomba Uso de PTFE para roscas cinta aislante...

Страница 17: ...cloruro de polivinilo de 1 1 4 en la parte delantera de la bomba 11 Aplique 2 3 vueltas de cinta de PTFE en las roscas macho de la conexi n de descarga en T Utilizando una llave para tubos enrosque la...

Страница 18: ...m s de los materiales generales para pozos poco profundos s lo para lanzas extractoras Suficiente tuber a galvanizada de 1 1 4 y manguitos de tuber a de hincar como para llegar desde el fondo del pozo...

Страница 19: ...de profundidad Sin embargo la bomba para pozos profundos de 1 2 o de 3 4 caballo de fuerza tambi n se puede utilizar para profundidades menores a 70 pies 21 3 metros Materiales generales necesarios pa...

Страница 20: ...de pl stico de la bomba Aseg rese de que todos los burletes en la tuber as de aspiraci n sean impermeables y herm ticos Si la tuber a de aspiraci n aspira aire la bomba no podr sacar agua del pozo 13...

Страница 21: ...dor Mantenimiento Drenado para dar servicio o para invierno Se deber drenar la bomba antes de desconectarla para darle servicio o cuando haya peligro de que se congele C mo drenarlo Saque el tap n de...

Страница 22: ...congeladas Descongele las tuber as Entierre las tuber as debajo de la l nea de congelaci n Caliente el recinto de bombas o el foso La v lvula de pie y o el colector est n enterrados en arena o en lodo...

Страница 23: ...profundo Bombas de pozo poco profundo CL520 CL100 CLTS5 CLTS10 Descripci n de la pieza 1 2 HP 1 HP 1 2 HP 1 HP Juego de junta y aro t rico RPK 35 RPK 35 RPK 35 RPK 35 Juego de acondicionamiento RPK 20...

Страница 24: ......

Отзывы: