Operation
Open a faucet or two in
the house. Turn regulator
adjustment screw down tight.
Start motor. If pump is properly
primed, a high pressure will
immediately show on the
pressure gauge. With pump
operating at high pressure,
slowly unscrew regulator stem
until maximum water flow
is obtained without dropping to zero. If pressure falls
completely, retighten stem and readjust. Steady pressure
must not be less than 24 PSI for the CL520 and 32 PSI
for the CL100. If no pressure shows, stop motor, remove
pressure regulator from pump, add more water, and
try again.
NOTICE In illustration at right, pressure gauge and tube
coming from pressure switch swap locations when used
in a deep well application.
If you install your pump with a 2" single-pipe
(“Packer”) jet, please follow the installation instructions
included with the Packer jet kit.
Maintenance
Draining for Servicing or for Winter
The pump should be drained before it is disconnected for
servicing or if it is in danger of freezing. To drain:
• Remove drain plug from bottom of pump case.
• Remove discharge tee to vent the pump.
• Drain all piping to a point 3 feet (1 meter) below
ground level.
Risk of explosion . If you change pressure
switch settings, set the cut-off pressure low enough to
shut off the pump. If a valve shuts off and the cut-off
setting is too high, the pump will run continuously
without water flow, causing overheating and possible
explosion which can cause serious burns and damage.
Fuse Box
or Circuit
Breaker
Pressure
Regulator
Pressure
Tank
Well
Seal
Twin
Ejector
Pressure
Gauge
Pressure
Switch
Foot
Valve
REGULATOR
STEM
NOTICE Plastic shipping fixture is used to prevent movement in shipment only. Do not return pump if shipping
fixture becomes cracked, as pump performance will not be affected.
Operation • Maintenance
10