Symptom

Possible Cause(s)

Corrective Action

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, disconnected, or 
wired incorrectly 

Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and 
tighten all wiring.

 Risk of electric shock . Can shock, burn or kill. Capacitor 

voltage may be hazardous. To discharge capacitor, hold insulated handle 
screwdriver BY THE HANDLE and short capacitor terminals together. Do not 
touch metal screwdriver blade or capacitor terminals. If in doubt, consult a 
qualified electrician.

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and overload 
kicks off

Motor is wired incorrectly

Refer to instructions on wiring.

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small (See 
Electrical / Wiring Chart).

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no water is 
delivered*

Pump in new installation did not pick up 
prime through:
1. Improper priming
2. Air leaks
3. Leaking foot valve or check valve

In new installation:
1. Re-prime according to instructions.
2.  Check all connections on suction line, AVC, and ejector with soapy water or 

shaving cream.

3. Replace foot valve or check valve.

Pump has lost prime through:
1. Air leaks
2. Water level below suction pipe inlet

In installation already in use:
1. Check all connections on suction line and shaft seal.
2.  Lower suction line into water and re-prime. If receding water level in well 

exceeds 25’ (7.6M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller.

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are buried in 
sand or mud

Raise foot valve and/or strainer above bottom of water source. Clean foot valve 
and strainer.

Water level is too low for shallow well 
setup to deliver water

A deep well jet will be needed if your well is more than 25’ (7.6M) depth to 
water.

Pump does not deliver water to 
full capacity (Also check point 3 
immediately above)

Water level in well is lower than estimated

A new nozzle and venturi combination may be needed.

Steel piping (if used) is corroded or limed, 
causing excess friction

Replace with plastic pipe where possible, otherwise with new steel pipe.

Piping is too small in size

Use larger piping.

Pump delivers water but does 
not shut off or pump cycles too 
frequently

Pressure switch is out of adjustment or 
contacts are welded together

DISCONNECT POWER; adjust or replace pressure switch.

Faucets have been left open

Close faucets.

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller.

Standard pressure tank is waterlogged and 
has no air cushion

Drain tank to air volume control port. Check AVC for defects. Check all 
connections for air leaks.

Pipes leak

Check connections.

Foot valve leaks

Replace foot valve.

Pressure switch is out of adjustment

Adjust or replace pressure switch.

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved. Using 
tire pressure gauge, check air pressure in tank at valve stem located on the tank. 
If less than pressure switch cut-in setting (30-50 PSI), pump air into tank from 
outside source until air pressure is 2 PSI less than cut-in setting of switch. Check 
air valve for leaks (use soapy solution) and replace core if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with soapy water.

Well is gaseous

Consult factory about installing a sleeve in the well.

Intermittent over-pumping of well. (Water 
drawn down below foot valve.)

Lower foot valve if possible, otherwise restrict pump discharge.

* Stop pump; then check 
prime before looking for 
other causes. Unscrew 
priming plug and see if 
water is in priming hole.

Troubleshooting 11

Содержание CL100 1 HP

Страница 1: ...Poco Profundo CLTS5 1 2 HP CLTS10 1 HP Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para...

Страница 2: ...ump If in doubt consult a qualified electrician General Safety Risk of burns Do not touch an operating motor Motors are designed to operate at high temperatures To avoid burns when servicing pump allo...

Страница 3: ...plications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contam...

Страница 4: ...mp from power before servicing or handling pump Remove the cover from the pressure switch Connect the bare copper ground to the ground screw in the pressure switch Connect the power supply to the term...

Страница 5: ...ow Well Pump For wells 25 feet or less in depth the 1 2 HP CLTS5 and 1 HP CLTS10 pumps are recommended However the 1 2 HP CL520 and 1 HP CL100 convertible pumps may be adapted to shallow wells with an...

Страница 6: ...pe needed to connect the PVC elbow to the 1 1 4 male PVC adapter in the front of the pump 11 Apply 2 3 wraps of PTFE tape to the male threads on the discharge tee Using pipe wrench thread 1 discharge...

Страница 7: ...on Materials needed in addition to Shallow Well General Materials for Well Points only Enough galvanized 1 1 4 pipe and drive couplings to reach from bottom of well to one foot above ground level One...

Страница 8: ...than 25 but not exceeding 70 feet in depth the 1 HP convertible deep well pump is recommended However the 1 2 HP deep well pump may also be used for depths not exceeding 70 feet General materials need...

Страница 9: ...tions to the pump itself Do not use pipe joint compounds on plastic pumps they can react with the plastic in pump components Make sure that all pipe joints in the suction pipe are air tight as well as...

Страница 10: ...tions included with the Packer jet kit Maintenance Draining for Servicing or for Winter The pump should be drained before it is disconnected for servicing or if it is in danger of freezing To drain Re...

Страница 11: ...strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well setup to deliver water A deep wel...

Страница 12: ...1 3 12 3 13 14 Overhaul Kit Deep well Ref No 1A 2 4 5 8 9 10 11 12 Ejector Kit Deep well Ref No 6 2 7 13 5 14 2 16 17 18 2 19 2 Pump Body Assembly 313 Ref No 2 6 10 15 16 1 4 NPT Plug 2 1 2 NPT Plug P...

Страница 13: ...est n dise ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier compon...

Страница 14: ...de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bombas cloacales que hay...

Страница 15: ...rta del interruptor de presi n Conecte el conductor de cobre sin revestimiento al tornillo de conexi n a tierra en el interruptor de presi n Conecte el suministro el ctrico a las terminales con la pal...

Страница 16: ...cordatorio Todas las juntas y conexiones deber n ser herm ticas Una nica fuga del tama o de un orificio de alfiler evitar el funcionamiento adecuado de la bomba Uso de PTFE para roscas cinta aislante...

Страница 17: ...cloruro de polivinilo de 1 1 4 en la parte delantera de la bomba 11 Aplique 2 3 vueltas de cinta de PTFE en las roscas macho de la conexi n de descarga en T Utilizando una llave para tubos enrosque la...

Страница 18: ...m s de los materiales generales para pozos poco profundos s lo para lanzas extractoras Suficiente tuber a galvanizada de 1 1 4 y manguitos de tuber a de hincar como para llegar desde el fondo del pozo...

Страница 19: ...de profundidad Sin embargo la bomba para pozos profundos de 1 2 o de 3 4 caballo de fuerza tambi n se puede utilizar para profundidades menores a 70 pies 21 3 metros Materiales generales necesarios pa...

Страница 20: ...de pl stico de la bomba Aseg rese de que todos los burletes en la tuber as de aspiraci n sean impermeables y herm ticos Si la tuber a de aspiraci n aspira aire la bomba no podr sacar agua del pozo 13...

Страница 21: ...dor Mantenimiento Drenado para dar servicio o para invierno Se deber drenar la bomba antes de desconectarla para darle servicio o cuando haya peligro de que se congele C mo drenarlo Saque el tap n de...

Страница 22: ...congeladas Descongele las tuber as Entierre las tuber as debajo de la l nea de congelaci n Caliente el recinto de bombas o el foso La v lvula de pie y o el colector est n enterrados en arena o en lodo...

Страница 23: ...profundo Bombas de pozo poco profundo CL520 CL100 CLTS5 CLTS10 Descripci n de la pieza 1 2 HP 1 HP 1 2 HP 1 HP Juego de junta y aro t rico RPK 35 RPK 35 RPK 35 RPK 35 Juego de acondicionamiento RPK 20...

Страница 24: ......

Отзывы: