CountyLine 102890199 Скачать руководство пользователя страница 12

Warranty 12

Retain Original Receipt for Warranty Eligibility

Limited Warranty
This Limited Warranty is effective January 1, 2013 and replaces all undated warranties and warranties dated before 

January 1, 2013.
CountyLine warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in 

material and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within 

twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or 

replaced at CountyLine’s option, subject to the terms and conditions set forth herein. Note that this limited warranty applies 

to manufacturing defects only and not to ordinary wear and tear. All mechanical devices need periodic parts and service to 

perform well. This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility 

is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair 

or replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per 

purchase). Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact CountyLine Customer Service 

at 800-535-4950.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet 

where it was purchased immediately after the discovery of any alleged defect. CountyLine will subsequently take corrective 

action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the 

warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.
Sewage Pumps
DO NOT return a sewage pump (that has been installed) to your retail store. Contact CountyLine Customer Service. Sewage 

pumps that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
•  Wear rubber gloves when handling the pump;
•  For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
•  Dispose of the pump according to local disposal ordinances.
Exceptions to the Twelve (12) Month Limited Warranty

Product

Warranty Period

CL106, CL108

90 days

CLTS33P, CLSU14

2 Years

4” Submersible Well Pumps

3 Years

CLVS50C, CLW750, Pressure Tanks

5 Years

General Terms and Conditions; Limitation of Remedies
You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not 

apply to the following: (1) acts of God; (2) products which, in CountyLine’s sole judgement, have been subject to negligence, 

abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or 

storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in 

the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth CountyLine’s sole obligation and purchaser’s exclusive remedy for defective products.
COUNTYLINE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, 

INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an 

implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal 

rights and You may also have other rights which vary from state to state.

CountyLine • 293 Wright Street • Delavan, WI U .S .A . 53115 

Phone: 800-535-4950 • Fax: 800-526-3757 • www .tractorsupply .com

Содержание 102890199

Страница 1: ...v 01 06 17 Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el f...

Страница 2: ...n must meet United States National Electrical Code Canadian Electrical Code and local codes as applicable for all wiring Disconnect electrical power supply before installing or servicing pump Make sur...

Страница 3: ...rge as wires carrying current to motor See Table 1 for recommended fuses and also see Cable Splicing Motor is supplied with copper ground wire Splice to copper conductor that matches motor wire size s...

Страница 4: ...rload trips look for 1 Shorted capacitor 2 Voltage problems 3 Overloaded or locked pump NOTICE Use only control box specified for your pump Make sure motor and control box match Table 3 Failure to do...

Страница 5: ...Make four passes with the tape when finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the wire see Figure 5 NOTICE Since the tightly...

Страница 6: ...ed in designated location Most submersible motors will include a ground lead for connection Other motors will have designated location on motor bracket 4 Use only submersible cable supplied by pump ma...

Страница 7: ...s relief valve between pump and tank NOTICE Allowing pump or piping system to freeze may severely damage pump and will void warranty Protect pump and entire piping system including pressure tank from...

Страница 8: ...on Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6 m See table 6472 1111 Figure 11 Typic...

Страница 9: ...s Electrical disconnect Pre charged tank Pressure switch Pressure gauge To house service Relief valve Union Gate valve 6471 1111 Figure 12 Typical Pre Charge Tank Installation Cut In PSI Cut Off PSI P...

Страница 10: ...ontrol box Check control box wiring diagram against incoming power hookup Reconnect leads to match wiring diagram in control box cover Check drop cable color coding Reconnect drop cable so cable color...

Страница 11: ...ee valve if installed backwards reverse it Low water level Determine lowest water level in well while pump is running and compare to pump depth setting Lower pump further into well but at least 5 1 6m...

Страница 12: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Страница 13: ...de instalar la bomba o de realizar tareas de reparaci n y mantenimiento Verifique que la tensi n de l nea y la frecuencia del suministro de corriente el ctrica coincidan con la tensi n y la frecuenci...

Страница 14: ...alme del cable El motor viene equipado con un cable de cobre de puesta a tierra Empalme este cable a tierra a un conductor de cobre que concuerde con el tama o del hilo del motor especificado en los T...

Страница 15: ...se dispara verifique que no haya 1 Un capacitor en corto circuito 2 Problemas de tensi n 3 Bomba sobrecargada o bloqueada AVISO Use solamente la caja de control dise ada para usar con la bomba Aseg r...

Страница 16: ...ase la cinta cuatro veces Es decir cuando termine tendr cuatro capas de cinta envueltas firmemente alrededor del cable Presione los bordes de la cinta firmemente contra el cable consulte la Figura 5 A...

Страница 17: ...otores sumergibles incluyen un conductor a tierra para la conexi n Otros motores tendr n un lugar designado en el soporte del motor 4 Use solamente cables sumergibles suministrados por el fabricante d...

Страница 18: ...tanque AVISO Si se permite que la bomba o el sistema de tuber as se congelen existe el riesgo de provocar da os graves en la bomba y esto invalidar la garant a Proteja la bomba y todo el sistema de tu...

Страница 19: ...que est ndar Distancia de la v lvula de retenci n al orificio de purga superior Capacidad del tanque en galones l distancia en pies m 42 159 2 6 82 310 4 3 9 120 454 2 5 1 5 Uni n V lvula de alivio V...

Страница 20: ...ol box 3 wire models Electrical disconnect Pre charged tank Pressure switch Pressure gauge To house service Relief valve Union Gate valve 6471 1111 Figura 12 Instalaci n t pica para un tanque de presi...

Страница 21: ...n de corriente el ctrica de entrada Vuelva a conectar los conductores para que coincidan con el diagrama de cableado en la tapa de la caja de control Verifique los c digos de color del cable de segre...

Страница 22: ...nivel del agua Determine el nivel m s bajo de agua en el pozo cuando la bomba est marchando y comp relo con la graduaci n de profundidad de la bomba Baje la bomba a mayor profundidad en el pozo pero...

Страница 23: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Страница 24: ......

Отзывы: