2.3 Communication Settings
2.3.1 Dip Switch Location.
Before installation and use, the unique address for each dome and the communication protocol including
transmission speed (baud rate) should be set to correspond with the chosen control system. In order to set the
corresponding dip-switches remove the camera liner as previously illustrated and locate the two Dip-Switch
rows (8 & 4) behind the camera module on the main PCB as illustrated.
2.3.2 Setting the address, protocol and baud rate for each dome device.
Note: The illustration shows the two Dip-Switches.
The switch on the left (8 position) is for the dome
address while the switch on the right is for the
protocol and baud rate settings. See Section 2.3.3-4
The Table in the illustration provides the settings
for the two protocols supported, Pelco D and
Pelco P as well as the baud rate settings.
This illustration demonstrates the settings for
Dome Address 1, with Protocol Pelco P at a baud
rate of 4800 setting.
CAUTION:
The protocol and baud rate of dome device should match the settings of the controller.
In order for the settings to take effect the dome must be power cycled after each change.