51
AGUADENS
COSMOGAS
8.1 - General recommendations
It is recommended to perform regular yearly maintenance of
the appliance for the following reasons:
- to maintain high yield and therefore save fuel;
- to maintain a high level of safety;
- to maintain the level of environmental compatibility of the
combustion high;
In order to maintain maintenance frequency, the parameter
2080
is present in the installer menu (see chapter
7.10), which is used to activate the maintenance call
(Service) along with parameter
2081
which is used to
set the operating days and which must pass between one
intervention and the next. The control system identifies the
operating days, verifying the burner activity time.
Proceed as follows to activate the call service:
1.- access the Installer menu (see chapter 7.10)and set
parameter
2080
on
0n
;
2.- access parameter
2081
and set the appliance
operating days which must pass between one call and
the next.
The call will be completed with
SEr
on the display. To
remove the wording
SEr
and renew the call period,
operate as follows:
1.- access the “Installer menu”;
2.- access the parameter
2080
, set it on
rESE
and
press the RESET key.
3.- exit the Installer menu by pressing the RESET key for 5
seconds.
The call time is now renewed and
SEr
appears on the
display.
ATTENTION !!! Appliance maintenance must
only be performed by a professionally qualified
technician.
ATTENTION !!! Before every maintenance
operation, disconnect the appliance from the electric
power supply, using the relevant switch in the vicinity.
ATTENTION !!! Close the gas isolation valve
before any maintenance operation
8 - MAINTENANCE