43
AGUADENS
COSMOGAS
7 - USE
Parameter
Parameter Description
M.U.
1001
Domestic hot water outlet temperature 1
°C
1002
Domestic hot water outlet temperature (or storage tank temperature, if present)
°C
1003
No function
/
1004
No function
/
1005
Domestic hot water outlet temperature 2 (safety sensor)
°C
1006
Exhaust flue temperature
°C
1007
Cold water inlet temperature
°C
1008
Ionisation current
uA
1009
Status of the pump inside the appliance
ON/OFF
1010
No function
/
1011
No function
/
1012
No function
/
1013
No function
/
1014
Exhaust flue temperature 2 (safety sensor)
°C
1040
Current rotation speed of the fan
rpm
1041
Fan rotation speed on ignition
rpm
1042
Fan rotation speed in minimum power mode
rpm
1043
Fan rotation speed in maximum power mode
rpm
1051
Latest block condition recorded (Loc) (see chapter 7.11.1)
/
1052
Latest error condition recorded (Err) (see chapter 7.11.2)
/
1053
Number of times the burner has lost the flame
n°
1055
Number of failed burner ignitions
n°
1056
No function
/
1057
Number of hours worked in domestic hot water mode
h x 10
1058
Number of burner working days
days
1059
Interval of time between the last two blocking errors (Err)
1
value in minutes;
2
value in hours;
3
value in days;
4
value in weeks;
1060
Interval of time between the last two blocks (Loc)
1061
Current rotation speed of the domestic hot water turbine
rpm
1062
Current domestic hot water flow rate
l/min
7.9 - “User menu” Parameters
To access the “User menu” follow that reported in paragraph 7.4.
The following parameters can be queried in this menu: