35
AGUADENS
COSMOGAS
ATTENTION !!!
If you smell gas:
A - Do not switch on any electric device, telephone
included or any object that can cause sparks;
B - Immediately open doors and windows causing
a current of air that quickly cleans the gas from
the room;
C - From another room, or from a neighbour’s,
immediately call a professionally qualified
technician or the gas supply company. Call the
Fire Service if the former are not available.
24.- check the supply gas pressure, following the procedure
in paragraph 6.6;
25.- open the CO2 adjustment screw completely (see figure
6.14 detail “A”);
26.- control and adjust the CO2, following the procedure in
paragraph 6.8;
27.- instead of the label that identified the old state of
adjustment, apply the sticker onto the front casing of
the appliance (see figure 6.6), certifying the appliance’s
new state of adjustment, as follows: apply label “B” if the
appliance has been converted from NATURAL GAS to LP
GAS; apply label “A” if the appliance has been converted
from LP GAS to NATURAL GAS.
B – Microswitch
Figure 6.5 - Positioning the microswitch
A
B
020002.01.043
ON
OFF
6 - OPERATING
Model
Type
of gas
Setting
parameter
3002
Gas supply
minimum
pressure
(mbar)
Gas supply
maximum
pressure
(mbar)
Gas nozzle
diameter
(mm)
CO2
Maximum
power
(%)
CO2
Minimum
power
(%)
O2
Maximum
power
(%)
O2
Minimum
power
(%)
16
NAT
50
15
27
4,9
9,0 ±
0,3
8,5 ±
0,2
4,8 ±
0,2
5,5 ±
0,2
LPG
51
25
45
3,7
10,5 ±
0,3
10,0 ±
0,2
4,8 ±
0,2
5,6 ±
0,2
22
NAT
52
15
27
6,7
9,0 ±
0,3
8,5 ±
0,2
4,8 ±
0,2
5,5 ±
0,2
LPG
53
25
45
5,2
10,5 ±
0,3
10,0 ±
0,2
4,8 ±
0,2
5,6 ±
0,2
27
NAT
54
15
27
8,0
8,7 ±
0,3
8,3 ±
0,2
4,7 ±
0,2
5,4 ±
0,2
LPG
55
25
45
6,0
10,1 ±
0,3
9,9 ±
0,2
4,7 ±
0,2
5,5 ±
0,2
37
NAT
54
15
27
10,0
8,7 ±
0,3
8,3 ±
0,2
4,7 ±
0,2
5,4 ±
0,2
LPG
55
25
45
6,5
10,1 ±
0,3
10,8 ±
0,2
4,7 ±
0,2
5,8 ±
0,2
Figure 6.6 - Labels certifying the new status of adjustment of the appliance
Figure 6.7 - Correspondence table for the parameter
3002
and the operating values