46
AGUADENS
COSMOGAS
7.11 - Diagnostics
During normal operation of the appliance, the visual display
in figure 7.1 continuously shows the state of work of the
appliance, via the following indications:
7 - USE
Parameter
Parameter Description
Display on visual display “H” in figure 7.1
AFro
Anti-freeze function active
Appliance temperature (°C)
AttE
Appliance not in block but in attention mode
Attention code (see chapter 7.11.3 for decoding)
Fixed on = Domestic hot water service on but not active
On flashing = Domestic hot water service on and active
Domestic hot water temperature (°C)
Loc
Appliance blocked. To reset, press
RESET
. If the block occurs
frequently, contact a professionally qualified technician
Block code (see chapter 7.11.1 for decode)
Err
Appliance in error mode. Functioning can only be restored by
solving the cause of the anomaly. Contact a professionally
qualified technician
Error code (see chapter 7.11.2 for decode)
ALEg
Anti-legionella function running (see chapter 5.12.1).
It will end on reaching the water temperature of 60°C inside the
storage tank.
Storage tank temperature (°C)
SEr
Maintenance request for the appliance
Appliance temperature (°C)