a) Press the CHG HOLD key to pressurize the tested part and locate leaks applying soap solution.
b) Execute a leak test by switching the master and tested part
If a tested part was rejected but the leak can’t be located even by applying soap solution, switch the
tubing and fixtures of the MASTER-side and WORK-side. This helps find out whether the leak is from
the MASTER-side or WORK-side tubing or fixture.
If the polarity of the leak rate changes when tubing and fixtures of the MASTER and the WORK are
switched, a leak is more likely to locate in the tested part or fixture seal. Do this check with the
Master-Preset feature disabled.
Be sure to replace the tubing in original position when the check is completed.
If soap solution is used, be sure to wipe it off with a cloth.
NOTE
Do not apply soap solution to a vacuum pressure type tester.
Disconnect the tubing and fixture from the WORK-side port and apply
regulated micro-low pressure and soap solution to locate the leak.
NOTE
Содержание LS-1866
Страница 2: ......
Страница 6: ......
Страница 22: ......
Страница 34: ......
Страница 56: ......
Страница 62: ......
Страница 71: ...11 INTERFACE 69 g Typical PLC connection NPN h Typical connection with PLC PNP ...
Страница 88: ......
Страница 89: ...13 APPENDIX 87 1 13 3 APPENDIX 1 13 3 1 1 E EX XT TE ER RN NA AL L A AP PP PE EA AR RA AN NC CE E ...