The remote ON/OFF function is incorporate in the input circuitry and operated with RC and GND.
If positive logic control is required , order the power supply with "-R" option.
■
When remote on/off function is not used, please open RC.
Table. 7.1.1
Specification of
Remote ON/OFF
Fig. 7.1.1
Internal circuitrys of
Remote ON/OFF
Fig. 7.1.2
RC connection
example
ON/OFF
logic
Between RC and GND
Output
voltage
Optional -R
Positive
L level (-0.2-0.3V) or short
OFF
H level (3.0-VIN) or open
ON
Standard
Negative
L level (-0.2-0.3V) or short or open
ON
H level (3.0-VIN)
OFF
BRNS 7-1
2.1 Pin configuration
7. Remote ON/OFF
Control
Circuit
22K
22K
RC
GND
+Vin
External
Circuit
Applications manual
For BRNS series