As shown in Fig.11.1.3, frequency synchronization is possible without using an outside clock.
Fig. 11.1.3
Example of CLK pin
connection
■
The maximum synchronization number is 5.
■
After the power supply which output CLK started, please start the synchronizing power supplies.
And when stop power supplies, you should stop the power supply which output CLK at first.
■
The max voltage of CLK pin is DC input voltage.
■
Applied voltage of the SYNC pin is equal to or larger than 5.5V to connect the ZD
CLK
(refer to Table.11.1.1)
BRNS 11-2
Applications manual