8
3.4 IGNITION, STARTING UP
Before using the stove make sure all the moving and movable parts are positioned correctly. Also
make sure the ash box is in position; remove any labels and adhesives from the glass, otherwise
they may leave a permanent mark.
Make sure that the voltage of the appliance corresponds with that of the mains power supply.
Then connect the cable supplied with the stove to a 220 V 50Hz power outlet and turn the
switch on the back to “I”= ON (see section 8 page 18). In this position the display will show the
message “Stove OFF” with the various preset functions.
Press the ON
button on the manual control panel of the stove for at least 3 seconds or on the
remote control; this will start the ignition cycle. At this point the display will show the message
Ignition No. 1 in progress; the resistance (“ign. torch”) will start to heat up to a high
temperature while pellets are deposited in the burner to start combustion.
The ignition cycle can be explained as follows:
1.
When ON is pressed on the control panel, the ign. torch will start to heat up as the
smoke exhaust fan starts at speed 6, for about 60 seconds.
2.
The pellets begin to fall into the burner at a continuous rate for about 160 seconds.
3.
The fan starts to work at 5 speed in order to reach the temperature setting for the
smoke temperature sensor.
4.
At this point the ign. torch goes off and the fan smokes it works at the most (6
speed) for 3,30 minutes for to turn on the pellet.
5.
The stove starts the selected recipe and power.
6.
At temperatures below 3 ° C too low for the heating element to glow or temporary
non-functionality of the resistance can be used to ignite the firelighter. Insert a piece
of the crucible firelighter well lit, close the door and press ON / OFF.
IMPORTANT: the startup stage lasts 1 CYCLE of 27 minutes before signalling error 1. After this
stage the display will show the message Stove Lit, Automatic or Manual mode, Date and Time, and
it will be possible to make adjustments to the combustion. The stove is normally lit after 3 minutes.
IMPORTANT: the ROOM circulation fan will start as soon as the temperature of the exhaust smoke
will be 80°C.
If the stove is not lit within 1 cycle the message error1 will appear. The possible causes are:
No pellets
Pellets blocked
Grate obstructed by dirt
Faulty resistance (ign. torch).
Содержание MT28
Страница 25: ...25 8 ELECTRICAL DIAGRAM...
Страница 29: ...29...