background image

 

23 

 
SENSOR SUBSTITUTION  

 

 

In  case  of  unbalanced  numbers  of  the 
temperature  smoke,  to  replace  the 

electronic  (see  substitution  electronic) 
and  eventually  the  smoke  temperature 

sensor  

 

 

 

BREAKDOWN TO THE THERMOSTAT OR THE RECYCLE FAN 

 

 

If  the  thermostat  of  control  recycle  fan 

doesn’t go off when the  temperature of 
stove 

arrives 

to 

70° 

centigrade 

replacing  the  thermostat  and  if  the 
problem 

persists 

to 

replace 

the 

electronic (see substitution electronic) 

 

SUBSTITUTION MOTO-ADAPTER  

 

 

If the moto-adapter doesn’t push on the 
pellet  despite  the  motor  turns,  it  wants 

to  say  that  some  gear  has  been 
damaged. In order to replace, to loosen 

the screw holds it fixed to the hinge. 

 
 

 
 

 

 
 

 
 

 

 

Содержание MT28

Страница 1: ...ng STQ18 Square covering STC18 Fantasy MT28 Round covering MTQ28 Square covering MTC28 Fantasy SERIAL NUMBER COSDEP di Vighesso Onorio S a s Via Copernico 25 36034 Malo VI ITALY Tel 0039 0445 605255 6...

Страница 2: ...ion menus 1 The DATE and TIME menu 11 2 The RECIPE SELECTION 12 3 The OPERATING MODE menu 13 4 the WEEKLY PROGRAMME menu 13 5 The TIMER COUNTDOWN menu 14 6 The SELECT LANGUAGE menu 15 7 The BUZZER men...

Страница 3: ...ll liability for incorrect installation or maintenance that may cause damage people or objects When carrying out cleaning and maintenance make sure that the appliance is switched off cool and disconne...

Страница 4: ...r tampered with the user shall be deemed liable IMPORTANT The appliance must be connected to a PE ground installation low voltage directives 73 23 CEE 93 98 CEE 1 4 DECLARATION OF CONFORMITY DECLARATI...

Страница 5: ...and a maximum length of 30 mm They have a maximum moisture content of 10 and a thermal value of 4 9 kW kg The best pellets on the market are a blend of beech and pine dust Standards DIN 51731 and NOR...

Страница 6: ...ONING THE STOVE The packed stove has already been assembled and is ready for installation We recommend keeping it upright when you move it using appropriate equipment and taking special care with the...

Страница 7: ...The smoke exhaust flue should follow a vertical path with no interruptions The inside diameter of the flue should be slightly greater than that of the stove The chimney flue should have the following...

Страница 8: ...as the smoke exhaust fan starts at speed 6 for about 60 seconds 2 The pellets begin to fall into the burner at a continuous rate for about 160 seconds 3 The fan starts to work at 5 speed in order to...

Страница 9: ...necessary to wait about 5 minutes for the pellets in the tank to reach the combustion chamber because the cylinder containing the feed screw has to be filled So if 1 cycle is insufficient switch off...

Страница 10: ...tioned on top of the stove to make it easy for the user to operate It has the following keys Main display this shows the various menu functions the date and time ignition and extinguishing To light up...

Страница 11: ...e UP key once to enter the DATE TIME menu press the SET key to confirm The day of the week will start flashing example Tuesday time 17 02 on 26 07 06 Tu 17 02 26 07 06 To change the day of the week pr...

Страница 12: ...power in order to compensate the deficiency of the pellet and therefore we have to use the recipe 5 Vice versa if the quality of the pellet is optimal quality we may use recipe 1 Comparable the power...

Страница 13: ...the abbreviations used in the programmer F number programmable time band 15 different time bands are available P number setting for programme setting Su Sunday Mo Monday Tu Tuesday We Wednesday Th Th...

Страница 14: ...time bands yet to be programmed Make sure that for each band that you skip through the key for enabling the programme is not pressed To scroll through the data quickly keep the corresponding key press...

Страница 15: ...UP key 6 times to change the language and enter the SELECT LANGUAGE menu SELECT LANGUAGE Press the RIGHT key to change the language Apart from Italian English French German and Spanish are available P...

Страница 16: ...ss SET to save and exit 9 SETTING THE IR infrared REMOTE CONTROL optional With the infrared remote control you can light and extinguish the stove from the comfort of your armchair To do this it is nec...

Страница 17: ...room temperature Ta and the preset temperature Ti e g as follows Tf Ta Ti 027 1 6 28 Press the UP key to bo to the next display which will show the screw speed Vc the air circulation fan speed Va the...

Страница 18: ...seconds to enter the SERVICE menu SERVICE Press the SET key to enter the menu At this point the display will show the values for the 5 preset smoke exhaust fan speed settings which are shown below ST1...

Страница 19: ...B F I E L D REGULATION SMOKE EXHAUST FAN Press RED key until seeing SERVICE menu After pressing SET key will appear the numbers for every speed If you decrease the planned numbers on the display the...

Страница 20: ...s pressed and the longer you have to increase the time To enter the EPROM to hold your stove blue just out in front eprom crush the green arrow to the right and keep it pressed until the code gets to...

Страница 21: ...e stove as specified in sections 5 1 5 2 and 5 3 Vacuum inside the smoke ducts with the help of a flexible flue brush Check the sealing gaskets on the door and glass Remove all the pipes clean them ch...

Страница 22: ...lateral panels as premise CANDLE SUBSTITUTION In order to replace the candle to unscrew the implantation screw and remove it from its place ELECTRONIC SUBSTITUTION In order to replace the Central Uni...

Страница 23: ...he thermostat of control recycle fan doesn t go off when the temperature of stove arrives to 70 centigrade replacing the thermostat and if the problem persists to replace the electronic see substituti...

Страница 24: ...mensions mm L49xP45xH89 L60xP45xH99 ST18 L54xP47xH99 STC18 L49xP45xH99 STQ18 L65xP60xH111 MT28 L59xP62xH111 MTC28 L55xP59Xh111 MTQ28 Weight with casing kg 108 111 147 Tank capacity kg 10 15 30 Pellet...

Страница 25: ...25 8 ELECTRICAL DIAGRAM...

Страница 26: ...it is absolutely necessary to remove the cause of overheating circulation fan not working excessive pellet feed etc with the help of a specialised technician if required When the temperature returns...

Страница 27: ...d repeat the operation Dirty grate USER clean carefully and repeat the operation Door open USER close the door and check the seal on the gaskets Glass broken TECHNICIAN change and check gaskets Too mu...

Страница 28: ...installer confirms that the product has been successfully tested after installation 4 The appliance has been used according to the instruction handbook supplied with the product The guarantee does no...

Страница 29: ...29...

Отзывы: