64 of 64
CORRADI S.R.L.
- INSTALLATION MANUAL - PERGOTENDA ® MAESTRO
REV.1 - 11.2019
EXAMPLE -
DETERMINATION OF THE WIND RESISTANCE ACCORDING TO THE LOADS AND THE DOWELS
Determination of maximum load on dowel.
Based on the dimensions of the structure and on the runner number, enter in the load tables 3,
4, 5 or 6 (according to the resistance at the desired wind speed) and identify the maximum
load on the single dowel. The obtained value is expressed in daN (1daN ≈ 1kg).
In the example below the input data are:
- Width: 550 cm
- Projection: 350 cm
- Runner number: 3
- Maximum desired wind speed: 49 km/h
Load comparison
The recommended load to be used as comparison is the
lower
one between the traction and the
shearing load.
The
lower
one between the maximum traction recommended load and the shearing one must be
higher than or
equal to the maximum load on single dowel identified from the load table relevant to the desired wind
speed. Vice versa, if the recommended load is lower than the maximum load on the dowel, assess the
following options: A) change the type of dowel
B) Duly reinforce the wall or the floor
C) Refer to a load table in case of a lower wind speed and assign the installed product to the relevant
wind resistance.
Attention
For a correct selection of the dowels,
exclusively refer to the manual provided by the fixing system
manufacturer.
ANCHORING SYSTEMS ON
STANDARDS, REGULATIONS, REFERENCE GUIDELINES
CONCRETE
GUIDELINES ETAG 001 QUALIFICATION AND DIMENSIONING OF METAL
ANCHORS FOR USE IN CONCRETE
TECHNICAL REPORT EOTA TR029 DESIGN OF BONDED ANCHORS
ETAG001 ANNEX E QUALIFICATION OF METAL ANCHORS FOR USE IN
CONCRETE UNDER SEISMIC ACTION
TECHNICAL REPORT EOTA TR045 DESIGN OF METAL ANCHORS FOR USE IN
CONCRETE UNDER SEISMIC ACTION
TECHNICAL REPORT EOTA TR020 EVALUATION OF ANCHORAGES IN CONCRETE
CONCERNING RESISTANCE TO FIRE
MASONRY
GUIDELINES ETAG 029 QUALIFICATION AND DIMENSIONING OF METAL
INJECTION ANCHORS FOR USE IN MASONRY
GUIDELINES ETAG 020 PLASTIC ANCHORS
Table 6 - Reference regulations for anchoring systems
Table 7 - Seismic performance categories for dowels
(ETAG001, Annex E)
For most of the applications category C2 of seismic performance is required (see table 7).
Width (cm)
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
1300
250
35
41
47
53
59
65
76
82
88
94
100
106
112
118
124
90
94
98
102
106
110
114
118
300
40
47
54
61
68
75
88
95
102
109
116
123
130
137
144
104
109
114
118
123
128
132
137
350
46
54
62
70
78
86
100
108
116
124
132
140
148
156
164
119
124
129
135
140
145
151
156
400
51
60
69
787
87
96
112
121
130
139
148
157
166
175
184
133
139
145
151
157
163
169
175
450
56
66
76
86
96
106
123
133
144
154
164
174
184
194
204
147
154
161
167
174
181
187
194
500
61
72
83
94
105
117
135
146
157
168
179
191
202
213
224
162
169
176
184
191
198
206
213
550
67
79
91
103
115
127
147
159
171
183
195
207
219
232
244
176
184
192
200
208
216
224
232
600
72
85
98
11
124
137
159
172
185
198
211
224
237
250
263
190
199
208
216
225
234
243
251
650
77
91
105
119
133
147
171
185
199
213
227
241
255
269
283
205
214
223
233
242
252
261
270
2 runners
3 runners
Pr
ojec
tion (
cm)
TABLE 4
- Maximum load in daN (1daN ≈ 1kg) on the single dowel (considering 2 dowels with counterplate (optional) or 4 dowels
without counterplate, for each foot support and 2 dowels per wall support) traction and shear (not combined) for a maximum wind
speed of 49 km/h (Beaufort Scale 6 - Class 3 according to EN 13561)
Abstract from table of maximum loads on single dowel
IT FOLLOWS THAT:
- MAXIMUM LOAD ON SINGLE DOWEL: 108 DAN
FOR THE DETERMINATION OF THE FIXING SYSTEM SEE PARAGRAPH ON THE SIDE.
Attention
The load indicated in the tables is the maximum load in daN on the single dowel (considering 2 dowels
for each support) for traction and shear (not combined)
Determination of Anchoring System
According to the type of support on which the dowels are to be fixed, refer to the selected fixing system
manufacturer manual to identify the most suitable system.
Dowels must comply with what stated in table 6.
SEISMIC
ACCELERATION
STRUCTURAL APPLICATIONS
NON-STRUCTURAL APPLICATIONS
USE CLASS IV
USE CLASS II/III
USE CLASS IV
USE CLASS II/III
<0.05 G
ETA (NO SEISMIC)
0.05-0.1
ETA C2
ETA C1
> 0.1G
ETA C2