RESERVED FOR QU
ALIFIED
TECHNICIANS
PROCEDURE FOR INSTALLING THE PLAN 75 – TYPE 1 MOTOR (ONLY FOR INSTALLERS)
WARNING
A qualified technician must initially adjust the motor.
When there is an electrical current, proceed with maximum
caution in accordance with the safety regulations in force.
When everything has been assembled, check that the
transmission system is properly connected: shafts, tubes, side
shafts and motor heads, with the sliders stacked at the top of
the awning. The motor is in neutral in this position. Before
assembling the awning proceed as follows:
1) TEMPORARY ADJUSTMENT OF THE OPENING LIMIT
SWITCH
Press push-button
A
with a screwdriver, turning it
slightly in order to secure the push-button. Press the push-
button panel to move the awning to ¾ of the runner. To store
the limit switch and quit the procedure press push-button
A
with a screwdriver and turn slightly to release, to store the limit
switch position and quit the procedure.
2) ASSEMBLING THE AWNING
Assemble the end and intermediate tubes to the structure,
securing them to the sliders.
3) ADJUSTING THE CLOSING LIMIT SWITCH, WITH AWNING
RETRACTED
Go back to the neutral position, retracting the awning until it
stops, then press push-button
B*
with a screwdriver, turning it
slightly in order to secure the push-button. Set the closing limit
switch 5 cm ahead of the neutral position, so that the sliders
are slightly slack. Press push-button
B
with a screwdriver and
turn slightly to release, to store the limit switch position and
quit the procedure.
4 - PERMANENT ADJUSTMENT OF THE OPENING LIMIT
SWITCH
Open the awning until it stops (temporary opening limit
switch) then press push-button
A
with a screwdriver, turning it
slightly in order to secure the push-button. Roll down the
awning until it reaches the right opening position. To store the
limit switch and quit the procedure press push-button
A
with a
screwdriver and turn slightly to release, to store the limit switch
position and quit the procedure..
*
Do not try to force the push-button if it does not move when
pressed, but ensure that the motor is positioned on the limit switch.
B
A
Panel
M1
1
2
3
1
3
2
insulated extend
button 230 V
A
B
Open male plug
supplied
insulated retract
button 230 V
WIRE TYPE
FG70R 3X1,5 mmq
WIRE TYPE
FG70R 3X1,5 mmq
W
ORK MUST BE C
ARRIED OUT B
Y
INST
A
LLER
PLAN 75 Motor
230 V/50 Hz
In= 0,97 A
Pn= 218 W
IP= 54
RETR
A
C
T
C
O
MMON
EX
TEND
2 - 04.2011
CORRADI S.P.A. - USER MANUAL - EXYL
42 of 109